3Com 3C13618 Command Reference Manual page 232

3com 3c13618: reference guide
Table of Contents

Advertisement

Table 4-3 Description of QSIG timers
timer-name
Timer
t301
T301
t302
T302
t303
T303
t304
T304
t305
T305
t308
T308
t309
T309
t310
T310
t313
T313
t316
T316
t322
T322
Normally, it is not necessary to change the values of QSIG signaling timers. If needed,
please do that with the guide of qualified technical personnel.
Table 4-4 Description of QSIG signaling timers
Timer
Start-up condition
T301
ALERTING message is received.
Start up for sending SETUP ACK
T302
message, re-start upon receiving the
INFORMATION message.
T303
Send the SETUP message.
The SETUP ACK message is received or
T304
send the INFORMATION message.
T305
Send the DISCONNECT message.
T308
Send the RELEASE message
Data link layer fault occurs and there are
T309
calls in "ACTIVE" status.
The CALL PROCEEDING message is
T310
received.
T313
Send CONNECT message
T316
Send the RESTART message
T322
Send the STATUS ENQUIRY message
Value range (in seconds)
30 to 1200
5 to 60
2 to 10
10 to 60
4 to 30
2 to 10
10 to 180
10 to 180
2 to 10
2 to 180
2 to 10
CONNECT message is received.
Send the CALL PROCEEDING, ALERTING, CONNECT
messages.
The message CALL PROCEEDING, CONNECT,
ALERTING, SETUP ACK or RELEASE COMPLETE is
received.
The message CALL PROCEEDING, ALERTING or
CONNECT is received
The message RELEASE or DISCONNECT is received.
The message RELEASE or RELEASE COM is received.
Data link layer re-establishes the connection.
The message ALERTING, CONNECT, PROGRESS,
DISCONNECT or RELEASE is received.
Receive the CONNECT ACKNOWLEDGE message
Receive the RESTART ACKNOWLEDGE message
The message STATUS, DISCONNECT, RELEASE, or
RELEASE COMPLETE is received.
Link Layer Protocol
Default value (in seconds)
180
15
5
20
15
5
90
30
5
5
5
Shutdown condition