Using the sdlc max-pdu command, you can configure the maximum length of SDLC
receivable frames. Using the undo sdlc max-pdu command, you can restore the
maximum. length of SDLC receivable frames to the default value.
SDLC maximum frame length is the maximum number of bytes of the receiving and
transmitting frames, with parity bit, start bit and end bit excluded.
Generally, the length is 265 for some PU2.0 equipment and 521 for IBM AS/400. We
often need to configure our equipment to have the same values as the connected
SDLC equipment.
Example
None

6.1.32 sdlc max-send-queue

Syntax
sdlc max-send-queue length
undo sdlc max-send-queue
View
Synchronous interface view
Parameter
length: Queue length of messages sent by SDLC, ranging from 20 to 255. By default,
the queue length of messages sent by SDLC is 20.
Description
Using the sdlc max-send-queue command, you can configure length of the SDLC
transmission queue. Using the undo sdlc max-send-queue command, you can
restore length of the SDLC transmission queue to the default value.
Before SDLC sends frames, it will put the frames in the transmission queue and then
send the frames in turn. If the transmitting queue is full, the packet will be dropped.