Change 3; Change 2; Change 1 - Agilent Technologies ENA Series User Manual

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Table A-7
Test Port Input (Trace Noise)
Description
300 kHz to 3 MHz
(source power level = +10 dBm)
3 MHz to 4.25 GHz
(source power level = +10 dBm)
4.25 GHz to 6 GHz
(source power level = +8 dBm)
6 GHz to 7.5 GHz
(source power level = +6 dBm)
7.5 GHz to 8.5 GHz
(source power level = +6 dBm)
*1.Trace noise is defined as a ratio measurement of a through, at IFBW = 3 kHz.
Change 4
The firmware revision A.03.54 or below does not support the following functions. Please
delete the descriptions about these functions in this manual.
o Auto Power Range set function

Change 3

The equipments that firmware revision at the factroy shipment is A.03.53 or below is not
eligible for the following specs. support the following functions. Please refer to original
attached manuals about them.
o Initial Source Port Control function

Change 2

Figure 16-4 dimensions of rear view was changed. Eligible serial numbers are
MY42100211 (for E5070B), MY42100407 (for E5071B) and later. For the earlier serial
number equipment, please refer to original attached manuals.

Change 1

The firmware revision A.03.0x does not support the following functions. Please delete the
descriptions about these functions in this manual
o User Characterized ECal
o Confidence check on calibration coefficients using ECal
o 4-port network embedding/de-embedding (Fixture simulator)
Appendix A
Specification
Manual Changes
Manual Changes
Supplemental Information
0.035 ° rms (23°C±5°C, typical)
0.05 ° rms (high temperature
mode: ON, typical)
0.007 ° rms (23°C±5°C, typical)
0.02 ° rms (high temperature
mode: ON, typical)
0.021 ° rms (23°C±5°C, typical)
0.035 ° rms (high temperature
mode: ON, typical)
0.021 ° rms (23°C±5°C, typical)
0.035 ° rms (high temperature
mode: ON, typical)
0.035 ° rms (23°C±5°C, typical)
0.05 ° rms (high temperature
mode: ON, typical)
605

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5070bE5071b

Table of Contents