Figure 11-3
Limit table
Step 6.
Press Add
values shown below.
Segment Parameter
Type
Begin Stimulus
End Stimulus
Begin Response
End Response
*1.The range in which stimulus values can be specified is from -500 G to +500 G. When a
*2.Once the stimulus value is specified, changing the sweep range of the E5070B/E5071B
*3.The range in which response values can be specified is from -500 M to +500 M. When a
*4.After the response value is specified, changing formats results in changing the units but
Chapter 11
to add a segment to the limit table and then specify the segment parameter
Description
Select the type of segment from the following:
OFF
MIN
MAX
Specify starting point for stimulus value on the limit line
*1*2
*1*2
Specify ending point for stimulus value on the limit line
Specify starting point for response value on the limit line
*3*4
Specify ending point for response value on the limit line
*3*4
value outside the range is entered, a suitable value within the range is specified.
does not affect the stimulus value.
value outside this range is entered, a suitable value within the range is specified.
not the value.
Segment not used for the limit test
Segment at which the minimum is specified
Segment at which the maximum is specified
Limit Test
Limit Test
377