Replacing the 8753ES with the E5070B/E5071B
Comparing Functions
Table F-5
Functions of the 8753ES vs. the E5070B/E5071B
Function
Measurement
Sweep
(cont'd.)
conditions
Smoothing
Electrical delay Transmission line
Phase offset
Setting sweep conditions for Couple/Uncouple
Trigger mode
746
Number of points
(except for the list frequency
sweep operation)
Sweep type
List frequency
Number of list
sweep
tables
Number of
segments per
table
Creation of a
table using
GPIB(SCPI)
command
Number of
points
Stepped/swept
mode
Sweep of
designated
segments.
Sweep time
IF bandwidth
Averaging
Value
8753ES
3, 11, 21, 26, 51, 101, 201, 401, 801,
1601
linear sweep, log sweep, list sweep,
power sweep, and CW time sweep
One for channels 1 and 3 and one for
channels 2 and 4, two in total
Up to 30
Creating a table using more than one
command
1 to 1601 points per segment
Up to 1601 points in total
stepped mode and swept mod.
Selectable only when list frequency
sweep is performed
Allowed
Automatic, Manual (definable from
the shortest time to 24 hours)
10 Hz, 30 Hz, 100 Hz, 300 Hz,
1 KHz, 3 kHz, 3.7 kHz, 6 kHz
Can be set from 1 to 999.
The smoothing aperture can be set
from 0.05% to 20%.
Compatible with coaxial cables and
waveguides
Any value from 0 to 10 seconds
Any value from -360° to +360°.
Channels 1 and 3 and channels 2 an 4
are always coupled. Channels 1 and
2 can be set either at Couple or
Uncouple.
Continuous, single, hold, specified
number of sweeps
E5070B/E5071B
*1
Arbitrary value from 2 to 1601
linear sweep, log sweep, segment
sweep, and power sweep
One for each channel (16 in total)
Up to 201
Creating a table using a single
command
2 to 1601 points per segment
*1
Up to 1601 points in total
stepped mode, swept mode, fast
stepped mode, and fast swept mode.
Selectable also when list frequency
sweep is not performed.
Not allowed (Always sweeps all
segments.)
Automatic, Manual (range of
definable sweep depends on sweep
condition)
10 Hz, 15 Hz, 20 Hz, 30 Hz,
40 Hz, 50 Hz, 70 Hz, 100 Hz,
150 Hz, 200 Hz, 300 Hz,
400 Hz, 500 Hz, 700 Hz, 1 kHz,
1.5 kHz, 2 kHz, 3 kHz, 4 kHz,
5
H
, 7
H
, 10
H
, 15
H
,
K
Z
K
Z
K
Z
K
Z
20
H
, 30
H
, 40
H
, 50
H
K
Z
K
Z
K
Z
K
70
H
, 100 kHz
K
Z
Can be set from 1 to 999.
The smoothing aperture can be set
from 0.05% to 25%.
Compatible with coaxial cables only
Any value from -10 to +10 seconds
Any value from -360° to 360°.
Traces in the same channel are
coupled; traces in different channels
are not coupled.
Continuous, single, hold
Appendix F
,
Z