Agilent Technologies ENA Series User Manual page 686

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Softkey Functions
Calibration Menu
Key Operation
(Continued)
Modify Cal Kit
Specify CLSs
Displays softkeys for setting the THRU standard class.
Thru
Displays softkeys for selecting standard for the THRU standard class that applies to all test ports.
Set All
Does not include
None
Includes
1. (Std
Name)
.
.
Includes 21.( Std Name) in the THRU standard class.
21. (Std
Name)
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 1 and 2. The
Port 1-2
lower-level softkeys are the same as those for
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 1 and 3. The
Port 1-3
lower-level softkeys are the same as those for
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 1 and 4. The
Port 1-4
lower-level softkeys are the same as those for
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 2 and 3. The
Port 2-3
lower-level softkeys are the same as those for
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 2 and 4. The
Port 2-4
lower-level softkeys are the same as those for
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 3 and 4. The
Port 3-4
lower-level softkeys are the same as those for
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting the TRL THRU standard. The
TRL Thru
lower-level softkeys displayed are the same as those for
TRL Reflect
Does not include
None
Includes
1. (Std Name)
.
.
Includes
21. (Std
Name)
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for setting the TRL LINE/MATCH standard. The
TRL Line/Match
lower-level softkeys displayed are the same as those for
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting the TRL calibration.
TRL Option
Selects the reference impedance.
Impedance
Selects the measurement data for the standard used to calculate the
Reference Plane
reference plane.
Returns to the softkey display screen one level higher.
Return
680
Function
in the THRU standard class.
1. (Std Name)
in the THRU standard class.
2. (Std Name)
.
.
in the TRL reflection standard class.
1. (Std Name)
in the TRL reflection standard class.
1. (Std Name)
.
.
in the TRL reflection standard class.
21. (Std Name)
:SENS{1-16}:CORR:COLL:CKIT:ORD:THRU
x,y,0
:SENS{1-16}:CORR:COLL:CKIT:ORD:THRU
x,y,1
:SENS{1-16}:CORR:COLL:CKIT:ORD:THRU
x,y,21
.
Set All
.
Set All
.
Set All
.
Set All
.
Set All
.
Set All
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLT
.
Thru
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLR 0
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLR 1
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLR
21
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLL
.
Thru
:SENS{1-16}:CORR:COLL:CKIT:TRL:IMP
:SENS{1-16}:CORR:COLL:CKIT:TRL:RPL
SCPI Command
.
.
.
.
Appendix D

Advertisement