Agilent Technologies ENA Series User Manual page 689

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Key Operation
(Continued)
Displays the softkey to execute the power calibration.
Power Calibration
Displays the softkey to select the test port you want to calibrate.
Select Port
Selects test port 1.
1
Selects test port 2.
2
Selects test port 3.
3
Selects test port 4.
4
Returns to the softkey display screen one level higher.
Cancel
Toggles on/off the power level error correction.
Correction
Executes the measurement of power calibration data.
Take Cal Sweep
Aborts the measurement of power calibration data.
Abort
Selects the channel of the power sensor you want to use for the
Use Sensor
measurement of power calibration data.
Sets the number of power level measurements per measurement
Num of Readings
point (averaging factor).
Sets the tolerance for power calibration.
Tolerance
Displays the softkey to set the loss correction.
Loss Compen
Toggles on/off the loss correction.
Compensation
Deletes the cursor line on the loss correction table.
Delete
Inserts a new segment above the cursor line on the loss correction
Add
table.
Displays the softkey to clear the loss correction table.
Clear Loss Table
Deletes all segments in the loss correction table.
OK
Returns to the softkey display in one level higher.
Cancel
Exports (writes in another software format) the content of the loss
Export to CSV
correction table as a CSV (comma separated value) format file.
File
Imports a saved CSV (comma separated value) format file into the
Import from CSV
loss correction table.
File
Returns to the softkey display in one level higher.
Return
Displays the softkey to set the calibration coefficient for the power sensor connected to channel A.
Sensor A Settings
Sets the value of the reference calibration coefficient.
Ref Cal Factor
Deletes the cursor line on the calibration coefficient table.
Delete
Inserts a new segment above the cursor line on the calibration
Add
coefficient table.
Displays the softkey to clear the calibration coefficient table.
Clear Loss Table
Deletes all segments in the calibration coefficient table.
OK
Returns to the softkey display in one level higher.
Cancel
Exports (writes in another software format) the content of the
Export to CSV
calibration coefficient table as a CSV (comma separated value)
File
format file.
Imports a saved CSV (comma separated value) format file into the
Import from CSV
calibration coefficient table.
File
Returns to the softkey display in one level higher.
Return
Appendix D
Function
Softkey Functions
Calibration Menu
SCPI Command
None
None
None
None
:SOUR{1-16}:POW:PORT{1-4}:CORR
:SOUR{1-16}:POW:PORT{1-4}:CORR:COLL
None
None
:SOUR{1-16}:POW:PORT{1-4}:CORR:COLL:A
VER
:SOUR:POW:PORT{1-4}:CORR:COLL:NTOL
:SOUR{1-16}:POW:PORT{1-4}:CORR:COLL:T
ABL:LOSS
:SOUR{1-16}:POW:PORT{1-4}:CORR:COLL:T
ABL:LOSS:DATA
:SOUR{1-16}:POW:PORT{1-4}:CORR:COLL:T
ABL:LOSS:DATA
None
:MMEM:STOR:PLOS{1-4}
:MMEM:LOAD:PLOS{1-4}
:SOUR:POW:PORT:CORR:COLL:ASEN:RCF
:SOUR:POW:PORT:CORR:COLL:TABL:ASEN:
DATA
:SOUR:POW:PORT:CORR:COLL:TABL:ASEN:
DATA
None
:MMEM:STOR:ASCF
:MMEM:LOAD:ASCF
683