Table F-5
Functions of the 8753ES vs. the E5070B/E5071B
Function
Macros
Creating macros
Automatic execution
System
Self-test
Internal clock
Beep sound
Measuring instrument mode
Printer /
Print range
Plotter output
Color settings
Line settings
Printer port
Others
Time domain transformation
Take4 mode
Mixer measurement function
Harmonics measurement
Key manipulation-related GPIB command
LAN
interface
protocol
function
GPIB
Debug mode
pass control
GPIB address setup
Parallel port
*1.The number of measurement points can be set to 20001 only when the channel/trace is set to
.
points
*2.All the marker values for non-active traces can also be displayed on each channel.
Appendix F
Replacing the 8753ES with the E5070B/E5071B
8753ES
Uses a test sequence.
Will execute if "AUTO" is given as
the name of the sequence 6.
Can be executed by using the front
panel and SCPI commands.
Available
On/Off setting definable for
completion of actions, warnings, and
limit test failures
Can be selected from a standard
network analyzer, external signal
source (automatic), external signal
source (manual), and tuned receiver.
Entire sheet, 1/4 of a sheet
Settings definable for the colors of a
trace, reference line, text, and
warning messages
Possible
Parallel port
Serial port
GPIB
Available
Available
Available
Available (Opt. 002)
GPIB commands that perform the
same processing as do the front panel
key and softkey manipulation.
Not available
Not available
Not available
Can be turned On/Off
Available
The addresses of the main body,
controller, external disk, LO control,
power meter, printer, and plotter can
be specified by using the GPIB
command and from the front panel.
Can be used as a printer or GPIO
connector.
Comparing Functions
E5070B/E5071B
Uses VBA.
Only auto loading is possible.
Can be executed by using the front
panel.
Available
On/Off setting definable for
completion of actions and warnings
Always a network analyzer
Entire sheet
Highlighting/No highlighting of all
elements
Always a solid line.
Parallel port
USB
Not available
Not available
Not available
Not available
10 Base-T and 100 Base-TX
TCP/IP
Telnet, SICL-LAN
Not available
Not available
The address of the main body can be
specified from the front panel.
The addresses of the power meter
can be specified by using the GPIB
command and from the front panel.
For printer use
1 Ch / 4 Tr 20001