Agilent Technologies ENA Series User Manual page 555

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Table 16-17
Rear Panel Information
Description
Handler I/O Port
*2
Line Power
Frequency
Voltage
VA Max
*1.USB Test and Measurement Class (TMC) interface that communicates over USB, complying with the IEEE 488.1
and IEEE 488.2 standards.
*2.A third-wire ground is required.
Table 16-18
EMC, Safety and Environment
Description
EMC
Safety
Chapter 16
Specifications and Supplemental Information
Supplemental Information
36-pin centronics, female; provides connection to handler system
47 Hz to 63 Hz
90 to 132 VAC, or 198 to 264 VAC (automatically switched)
350 VA max.
Supplemental Information
European Council Directive 89/336/EEC, 93/68/EEC
IEC 61326-1:1997 +A1:1998 / EN 61326-1:1997 +A1:1998
CISPR 11:1997 +A1:1999 / EN 55011:1998 +A1:1999
Group 1, Class A
IEC 61000-4-2:1995 / EN 61000-4-2:1995 +A1:1998
4 kV CD / 8 kV AD
IEC 61000-4-3:1995 / EN 61000-4-3:1996 +A1:1998
3 V/m, 80-1000 MHz, 80% AM
IEC 61000-4-4:1995 / EN 61000-4-4:1995
1 kV power / 0.5 kV Signal
IEC 61000-4-5:1995 / EN 61000-4-5:1995
0.5 kV Normal / 1 kV Common
IEC 61000-4-6:1996 / EN 61000-4-6:1996
3 V, 0.15-80 MHz, 80% AM
IEC 61000-4-11:1994 / EN 61000-4-11:1994
100% 1cycle
Note: The performance criterion B is adopted for ESD immunity test,
and criterion A for other immunity tests. Temporary deviation from test
limit due to accidental measurement of test signal is considered normal
performance.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
AS/NZS 2064.1/2 Group 1, Class A