Agilent Technologies ENA Series User Manual page 687

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Key Operation
(Continued)
Modify Cal Kit
Allows the user to label the calibration kit.
Label Kit
Displays softkeys for initializing the definition of calibration kit.
Restore Cal Kit
Restores the definition of the calibration kit selected by
OK
factory default settings.
Returns to the softkey display screen one level higher.
Cancel
Exports the contents of the calibration kit to a file.
Export Cal Kit...
Imports a saved calibration kit file.
Import Cal Kit...
Returns to the softkey display screen one level higher.
Return
Displays softkeys for extending ports.
Port Extensions
Displays softkeys for setting the auto port extension.
Auto Port
Extension
Displays softkeys for selecting the test port with which you want to perform the auto port extension.
Select Ports
Selects test port 1
Port 1
Selects test port 2
Port 2
Selects test port 3
Port 3
Selects test port 4
Port 4
Returns to the softkey display screen one level higher.
Return
Executes the measurement of the open standard.
Measure OPEN
Executes the measurement for all the selected ports.
All
Executes the measurement for test port 1.
Port 1
Executes the measurement for test port 2.
Port 2
Executes the measurement for test port 3.
Port 3
Executes the measurement for test port 4.
Port 4
Returns to the softkey display screen one level higher.
Return
Executes the measurement of the short standard.
Measure
SHORT
Executes the measurement for all the selected ports.
All
Executes the measurement for test port 1.
Port 1
Executes the measurement for test port 2.
Port 2
Executes the measurement for test port 3.
Port 3
Executes the measurement for test port 4.
Port 4
Returns to the softkey display screen one level higher.
Return
Sets the frequency calculated by the auto port extension function.
Method
Sets the current sweep range.
Current Span
Sets the frequency of the active marker.
Active Marker
Sets the arbitrary start value and stop value.
User Span
Sets the start value.
User Span
Start
Sets the stop value.
User Span
Stop
Returns to the softkey display screen one level higher.
Return
Appendix D
Function
to
Cal Kit
Softkey Functions
Calibration Menu
SCPI Command
:SENS{1-16}:CORR:COLL:CKIT:LAB
:SENS{1-16}:CORR:COLL:CKIT:RES
:MMEM:STOR:CKIT{1-20}
:MMEM:LOAD:CKIT{1-20}
:SENS{1-16}:CORR:EXT:AUTO:PORT 1
:SENS{1-16}:CORR:EXT:AUTO:PORT 2
:SENS{1-16}:CORR:EXT:AUTO:PORT 3
:SENS{1-16}:CORR:EXT:AUTO:PORT 4
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
:SENS{1-16}:CORR:EXT:AUTO:CONF CSPN
:SENS{1-16}:CORR:EXT:AUTO:CONF AMKR
:SENS{1-16}:CORR:EXT:AUTO:CONF USPN
:SENS{1-16}:CORR:EXT:AUTO:STAR
:SENS{1-16}:CORR:EXT:AUTO:STOP
681