Analysis Menu - Agilent Technologies ENA Series User Manual

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Analysis Menu

Key Operation
Displays softkeys for performing analysis functions.
Displays softkeys for setting up fixture simulator functions. The fixture simulator is software that uses
Fixture Simulator
measurement results to simulate various measurement conditions. The fixture simulator consists of the following
six functions: balanced/unbalanced conversion (use
), port impedance conversion (use
Matching
differential matching circuit (use
To use each of the above functions, each must be enabled at the same time you enable the fixture simulator using
the
Fixture Simulator
Enables or disables the fixture simulator function. When using one or more
Fixture Simulator
of the six functions provided with the fixture simulator, the fixture
simulator function must be enabled using this key along with all desired
functions.
Displays softkeys for setting the balanced measurement topology (the types of DUT ports and the connecting
*1
Topology
method to test the ports).
Displays softkeys for selecting the types of DUT ports in a balanced measurement.
Device
Evaluates mixed mode S parameters between a single-end (unbalanced)
SE-Bal
port and balanced port on the DUT. In the succeeding procedure, the
single-end port and the balanced port will be treated as port 1 on the DUT
(logical port 1) and port 2 on the DUT (logical port 2), respectively.
*2
Evaluates mixed mode S parameters between two balanced ports on the
Bal-Bal
DUT. In the succeeding procedure, the two balanced ports will be treated as
port 1 on the DUT (logical port 1) and port 2 on the DUT (logical port 2).
Evaluates mixed mode S parameters between two single-end (unbalanced)
*2
SE-SE-Bal
ports and balanced port on the DUT. In the succeeding procedure, the two
single-end ports will be treated as port 1 on the DUT (logical port 1) and
port 2 on the DUT (logical port 2), and the balanced port as port 3 on the
DUT (logical port 3).
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for selecting the analyzer port (test port) to which (single-end) port 1 on the DUT will be
Port1 (se)
connected. This key will be displayed only when
Selects test port 1 on the analyzer for connection with (single-end) port 1 on
1
the DUT.
Selects test port 2 on the analyzer for connection with (single-end) port 1 on
2
the DUT.
Selects test port 3 on the analyzer for connection with (single-end) port 1 on
3
the DUT.
*2
Selects test port 4 on the analyzer for connection with (single-end) port 1 on
4
the DUT.
Returns to the softkey display screen one level higher.
Cancel
*2
Displays softkeys for selecting the analyzer ports (test ports) to which (balanced) port 1 on the DUT will be
Port1 (bal)
connected. This key will be displayed only when
Selects test ports 1 and 2 on the analyzer for connection with (balanced)
1-2
port 1 on the DUT (ports a and b in Table 7-8 on page 294) respectively.
Selects test ports 1 and 3 on the analyzer for connection with (balanced)
1-3
port 1 on the DUT (ports a and b in Table 7-8 on page 294) respectively.
Selects test ports 1 and 4 on the analyzer for connection with (balanced)
1-4
port 1 on the DUT (ports a and b in Table 7-8 on page 294) respectively.
Selects test ports 2 and 1 on the analyzer for connection with (balanced)
2-1
port 1 on the DUT (ports a and b in Table 7-8 on page 294) respectively.
Appendix D
Function
Topology
Port Z Conversion
), and differential impedance conversion (use
Diff. Matching
key below.
or
SE-Bal
in the
Bal-Bal
Softkey Functions
Analysis Menu
SCPI Command
and
to set up), matching circuit (use
BalUn
), network de-embedding (use
De-Embedding
Diff. Z Conversion
:CALC{1-16}:FSIM:STAT
:CALC{1-16}:FSIM:BAL:DEV SBAL
:CALC{1-16}:FSIM:BAL:DEV BBAL
:CALC{1-16}:FSIM:BAL:DEV SSB
in the
menu is selected.
SE-SE-Bal
Device
:CALC{1-16}:FSIM:BAL:TOP:SBAL
:CALC{1-16}:FSIM:BAL:TOP:SSB
:CALC{1-16}:FSIM:BAL:TOP:SBAL
:CALC{1-16}:FSIM:BAL:TOP:SSB
:CALC{1-16}:FSIM:BAL:TOP:SBAL
:CALC{1-16}:FSIM:BAL:TOP:SSB
:CALC{1-16}:FSIM:BAL:TOP:SBAL
:CALC{1-16}:FSIM:BAL:TOP:SSB
menu is selected.
Device
:CALC{1-16}:FSIM:BAL:TOP:BBAL
:CALC{1-16}:FSIM:BAL:TOP:BBAL
:CALC{1-16}:FSIM:BAL:TOP:BBAL
:CALC{1-16}:FSIM:BAL:TOP:BBAL
Port
),
).
647