Sign In
Upload
Manuals
Brands
Agilent Technologies Manuals
Test Equipment
8960
Agilent Technologies 8960 Manuals
Manuals and User Guides for Agilent Technologies 8960. We have
9
Agilent Technologies 8960 manuals available for free PDF download: Reference Manual, Operation Manual, Manual Operation, Programming Manual, Manual, Installation Note
Agilent Technologies 8960 Reference Manual (786 pages)
10 Wireless Communications Test Set
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 10.58 MB
Table of Contents
Table of Contents
15
Measurements
33
Instrument Configuration Measurement Matrix
34
Access Probe Power Measurement Description
35
How Is an Access Probe Power Measurement Made
35
Considerations When Making Access Probe Power Measurements
35
Input Signal Requirements
35
Related Topics
36
Analog Transmit Power Measurement Description
37
How Is an Analog Transmit Power Measurement Made
37
Input Signal Requirements
37
Considerations When Making Manual Analog Transmit Power Measurements
37
Related Topics
37
Audio Analyzer Measurement Description
38
How Is an Analog Audio Measurement Made
38
De-Emphasis State
39
Expandor Reference Level
39
Trigger Source
39
Related Topics
40
Audio Analyzer Block Diagram
41
Related Topics
41
Audio Frequency Measurement Description
42
Considerations When Making Manual Audio Frequency Measurements
42
Related Topics
42
Audio Level Measurement Description
43
How Is an Audio Level Measurement Made
43
Related Topics
43
Channel Power Measurement Description
44
How Is a Channel Power Measurement Made
44
Channel Power Measurement Calibration
44
Channel Power Measurement Speed
44
Input Signal Requirements
44
Related Topics
45
Code Channel Timing and Phase Measurement Description
46
How Is a Code Channel Timing and Phase Measurement Made
46
Code Channel Time/Phase Measurement Graphical Display
48
Measurement Behavior
50
Input Signal Requirements
50
Related Topics
50
Digital Average Power Measurement Description
51
How Is a Digital Average Power Measurement Made
51
Digital Average Power Measurement Characteristics
51
Input Signal Requirements
51
Related Topics
51
Distortion Measurement Description
52
How Is a Distortion Measurement Made
52
Considerations When Making Manual Distortion Measurements
52
Related Topics
52
Frame Error Rate Measurement Description
53
How Is an FER (Frame Error Rate) Measurement Made
53
Confidence Level Description
53
Input Signal Requirements
53
Related Topics
54
Frequency Modulation (FM) Measurement Description
55
How Is a Frequency Modulation Measurement Made
55
Triggering
55
Distortion State and Distortion Fundamental Frequency Operation
55
Modulation Frequency State
55
Filter Type
56
Detector Type
56
De-Emphasis State
56
Expandor State
56
Related Topics
56
Frequency Stability Measurement Description
57
How Is a Frequency Stability Measurement Made
57
Operating Considerations
57
Input Signal Requirements
57
Worst Case Frequency Error
57
Triggering
57
Related Topics
57
Gated Power Measurement Description
58
What Is a Gated Power Measurement
58
How Is a Gated Power Measurement Made
58
Gated Power Measurement Behavior
61
Measurement Requirements
61
Related Topics
61
Handoff Waveform Quality Measurement Description
62
How Is a Handoff Waveform Quality Measurement Made
62
Measurement Behavior
62
Measurement Requirements
63
Related Topics
63
SINAD Measurement Description
64
How Is a SINAD Measurement Made
64
Considerations When Making Manual SINAD Measurements
64
Related Topics
64
Swept Audio Measurements Description
65
Description
65
Related Topics
67
TDSO Frame Error Rate Measurement Description
68
What Is a TDSO (Test Data Service Option) FER (Frame Error Rate) Measurement
68
How Is a TDSO FER Measurement Made
68
Possible Setup Issues
70
Related Topics
70
Tx Spurious Emissions Measurement Description
71
How Is a Tx Spurious Emissions Measurement Made
71
Tx Spurious Emissions Measurement Characteristics
71
Input Signal Requirements
71
Related Topics
72
Waveform Quality/Code Domain Measurement Description
73
How Is a Waveform Quality/Code Domain Power Measurement Made
73
Code Domain Power Graphical Display
74
Input Signal Requirements
75
Related Topics
75
Test Adherence to Standards
76
Standards Table
76
Measurement Related Configuration
81
Description
81
Related Topics
84
Call Processing
85
Active Cell Operating Mode
86
Active Cell Features
86
Related Topics
86
AVC Test Operating Mode
87
AVC Test Mode Operation
87
Related Topics
90
IS-2000 Test Operating Mode
91
Forward CDMA Channels Available in Test Mode
91
Related Topics
91
CW Operating Mode
92
CW Test Mode Operation
92
Related Topics
92
Configuring the F-Fch/Traffic Channel (Forward Fundamental/Traffic Channel)
93
Settable F-FCH Parameters
93
GPIB Examples
93
Operating Considerations
93
Related Topics
93
Configuring the F-Paging Channel (F-PCH)
94
Settable F-Paging Parameters
94
Fixed F-Paging Parameters
94
GPIB Examples
94
Operating Considerations
95
Related Topics
95
Configuring the F-SCH (Forward Supplemental Channel)
96
Settable F-SCH Parameters
96
Fixed F-SCH Parameters
96
GPIB Examples
96
Operating Considerations
96
Related Topics
96
Configuring the F-Pilot Channel (Forward PICH)
97
Settable F-Pilot Parameters
97
Fixed F-Pilot Parameters
97
GPIB Examples
97
Operating Considerations
97
Related Topics
97
Configuring the F-OCNS (Forward Orthogonal Channel Noise Simulator)
98
Settable F-OCNS Parameters
98
Fixed F-OCNS Parameters
98
GPIB Examples
98
Operating Considerations
98
Related Topics
98
Configuring the F-QPCH (Forward Quick Paging Channel)
99
Settable F-QPCH Parameters
99
Fixed F-QPCH Parameters
99
GPIB Examples
99
Operating Considerations
100
Related Topics
100
Configuring the F-Sync Channel (Forward SYNC)
101
Settable F-Sync Parameters
101
Fixed F-Sync Parameters
101
GPIB Examples
101
Related Topics
101
Establishing an Active Link with the Mobile Station
102
Making a Mobile Station Originated Call
102
Making a Base Station Originated Call
102
Related Topics
102
Performing a Handoff
103
Making a Handoff
103
Related Topics
103
Performing a Registration
104
Registering a Mobile Station
104
Related Topics
104
Programming
105
Step 1: Set up the Test Set
106
Fully Preset the Test Set
106
Declare Variables, Set Path Losses and Timeouts, Activate GPIB Debugger
107
Step 2: Configure Test Set and Mobile Station Parameters
108
Configure the Test Set Parameters
108
Configure the Mobile Station Parameters
108
Step 3: Set Measurement Parameters
109
Step 4: Make a Connection
110
Select an Example
110
Test Set Initiated Connection
110
Mobile Station Initiated Connection
110
Step 5: Initiate and Fetch Measurements
111
Initiate Measurements and Fetch Results
111
Step 6: Reconfigure Test Set and Mobile Station Connection Parameters
116
Reconfigure the Test Set
116
Reconfigure the MS
116
Step 7: End the Connection
117
End the Connection
117
Step 1: Set up the Test Set
119
Description
119
Step 2: Configure Test Set and Mobile Station Parameters
121
Description
121
Step 3: Set Measurement Parameters
125
Description
125
Step 4: Make Connection
130
Description
130
Step 5: Initiate and Fetch Measurements
135
Description
136
Step 6: Reconfigure Test Set and Mobile Station Connection Parameters
141
Description
141
Step 7: End Connection
143
Description
143
Programming an Access Probe Power Measurement
147
Programming Example
148
Returned Values
149
Related Topics
149
Programming an Analog Transmit Power Measurement
150
Programming Example
150
Returned Values
150
Related Topics
151
Programming an Audio Level Measurement
152
Programming Example
152
Returned Values
152
Related Topics
153
Programming an Audio Frequency Measurement
154
Programming Example
154
Related Topics
154
Programming a Channel Power Measurement
155
Programming Example
155
Returned Values
157
Related Topics
157
Programming a Code Channel Time/Phase Measurement
158
Programming Example
158
Related Topics
160
Programming a Digital Average Power Measurement
161
Programming Example
161
Returned Values
163
Related Topics
163
Programming a Distortion Measurement
164
Programming Example
164
Returned Values
165
Related Topics
165
Programming an FER (Frame Error Rate) Measurement
166
Programming Example
166
Related Topics
168
Programming a Frequency Modulation (FM) Measurement
169
Programming Example
169
Returned Values
169
Related Topics
170
Programming a Frequency Stability Measurement
171
Programming Example
171
Returned Values
171
Related Topics
172
Programming a Gated Power Measurement
173
Programming Example
173
Related Topics
175
Programming a Handoff Waveform Quality Measurement
176
Related Topics
176
Programming a SINAD Measurement
177
Programming Example
177
Returned Values
178
Related Topics
178
Programming a Swept Audio Measurement
179
Programming Example
179
Returned Values
180
Related Topics
180
Programming a TDSO Frame Error Rate Measurement
181
Programming Example
181
Related Topics
183
Programming a Tx Spurious Emissions Measurement
184
Programming Example
184
Returned Values
187
Related Topics
187
Programming a Waveform Quality/Code Domain Measurement
188
Programming Example
188
Related Topics
190
Preset Descriptions
191
Description
191
Related Topics
193
Receiver Control
194
Manual Receiver Control Parameters
194
Manual Vs. Automatic Receiver Control
194
Manual Receiver Control
194
Automatic Receiver Control
196
Effects on Receiver Control When Changing Operating Mode
196
Related Topics
196
Status Subsystem Overview
197
Description
198
Related Topics
215
Statistical Measurement Results
216
Description
216
Programming Example
216
Related Topics
216
Timeouts
217
Description
217
Timeout Values
217
Related Topics
217
Triggering of Measurements
218
Trigger Source Choices
218
Description
218
Related Topics
221
Integrity Indicator
222
Description
222
Example Program
225
Related Topics
225
Measurement Progress Report
226
Description
226
Example
226
Related Topics
226
Concurrent Measurements
227
Description
227
Related Topics
227
Invalid Measurement Results
228
Description
228
Dealing with Semicolon Separated Response Data Lists
229
Description
229
Measurement Event Synchronization
231
Description
231
Initiate:done
231
Advertisement
Agilent Technologies 8960 Reference Manual (648 pages)
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 8.32 MB
Table of Contents
Table of Contents
3
Measurements
29
Adjacent Channel Leakage Ratio Measurement Description
30
How Is an Adjacent Channel Leakage Ratio Measurement Made
30
Input Signal Requirements
30
Trigger Source
30
Measurement Calibration
31
Related Topics
31
Audio Level Measurement Description
32
How Is an Audio Level Measurement Made
32
Related Topics
32
Audio Analyzer Measurement Description
33
How Is an Analog Audio Measurement Made
33
De-Emphasis State
34
Expandor Reference Level
34
Trigger Source
34
Related Topics
34
Audio Analyzer Block Diagram
35
Related Topics
35
Audio Frequency Measurement Description
36
Related Topics
36
Channel Power Measurement Description
37
How Is a Channel Power Measurement Made
37
Input Signal Requirements
37
Trigger Source
37
Measurement Calibration
38
Related Topics
38
Distortion Measurement Description
39
How Is a Distortion Measurement Made
39
Related Topics
39
Loopback Bit Error Ratio Measurement Description
40
How Is a Loopback Bit Error Ratio Measurement Made
40
Mobile Station (UE) Control During FDD Test Mode Operation
40
Input Signal Requirements
40
Trigger Source
40
Related Topics
40
SINAD Measurement Description
41
How Is a SINAD Measurement Made
41
Related Topics
41
Thermal Power Measurement Description
42
How Is a Thermal Power Measurement Made
42
Input Signal Requirements
42
Trigger Source
42
Related Topics
43
Waveform Quality Measurement Description
44
How Is a Waveform Quality Measurement Made
44
Input Signal Requirements
44
Trigger Source
44
Measurement Calibration
44
Related Topics
45
Spectrum Emission Mask Measurement Description
46
What Is the Spectrum Emission Mask
46
How Is the Spectrum Emission Mask Measurement Made
46
Spectrum Emission Mask Measurement Results
47
Input Signal Requirements
48
Trigger Source
48
Measurement Calibration
48
Related Topics
48
Occupied Bandwidth Measurement Description
49
How Is the Occupied Bandwidth Measurement Made
49
Input Signal Requirements
49
Trigger Source
49
Measurement Calibration
49
Related Topics
49
Code Domain Measurement Description
50
How Is the Code Domain Measurement Made
50
Code Domain Measurement Results
50
Input Signal Requirements
51
Trigger Source
52
Measurement Calibration
52
Related Topics
52
Test Adherence to Standards
53
Thermal Power
53
Channel Power
53
Adjacent Channel Leakage Ratio
53
Waveform Quality
54
Loopback Bit Error Ratio
54
Spectrum Emission Mask
55
Code Domain
55
Occupied Bandwidth
56
What 3GPP W-CDMA Conformance Tests Are Supported
57
Related Topics
58
Amplitude Offset
59
Description
59
Related Topics
62
Call Processing
63
Active Cell Operating Mode
64
Active Cell Operating Mode Screen Description
64
Control Descriptions
65
Related Topics
65
FDD Test Operating Mode
66
UE (Mobile Station) Control During FDD Test Mode
66
Downlink Channel Settings
67
Noise Sources on the Downlink
68
Other Downlink Signal Settings
68
Uplink Settings
70
Receiver Control Settings
70
Related Topics
70
Cell off Operating Mode
71
Related Topics
71
CW Operating Mode
72
CW Test Mode Operation
72
Related Topics
73
Setting Cell Parameters
74
Changing Cell Parameters
74
GPIB Commands for These Settings
74
Changing Cell Parameters from the Front Panel
74
Related Topics
74
Setting Downlink Channel Codes and Levels
75
How to Set Channel Codes and Levels
75
GPIB Commands for Setting Downlink Channel Codes
76
GPIB Commands for Setting Downlink Channel Levels in Cell off Mode
76
GPIB Commands for Changing Connected Downlink Channel Levels
76
Changing Downlink Channel Codes and Levels from the Front Panel
77
Related Topics
77
Setting Downlink Power Levels
78
Current Level and Desired Level
78
GPIB Commands for Setting Downlink Power Levels
79
Related Topics
79
Setting Uplink Parameters
80
PRACH Parameters
80
Changing Uplink Parameters
80
GPIB Commands for Setting Uplink Parameters
80
Changing Uplink Parameters from the Front Panel
81
Related Topics
81
Setting Downlink Parameters
82
Channel Type
82
DTCH Data
82
Downlink Channel Number
82
Paging Indicator Channel (PICH) Data
82
Call Drop Timer State
82
Call Limit State
82
Signaling Radio Bearer Configuration
83
GPIB Commands for Setting DTCH Parameters
83
Related Topics
83
Setting Uplink Channel and Power Control
84
Changing Uplink Channel and Power Control Settings
84
GPIB Commands for Setting the Uplink Channel and Power Control
85
Related Topics
85
Establishing a Connection with the UE
86
Related Topics
86
How the Test Set Performs a Handoff
87
Related Topics
87
Programming
89
Programming: Getting Started Guide for E1963A W-CDMA Mobile Test Application Revision A.02
90
Introduction
91
Programming Flowchart
92
Conventions Used in this Getting Started Guide
93
How to Use this Getting Started Guide
93
Useful On-Line Links
94
About the Programming Examples Presented in this Guide
94
Step 1: Set up the Test Set
96
Initialize the Test Set
96
Set up General Operating Conditions
96
Step 2: Configure Test Set and UE Parameters
98
Set up the Cell Parameters
98
Set Generator Info Parameters
98
Set Uplink Parameters
99
Set up Call Parameters
99
Set Uplink Channel Levels
100
Step 3: Set Measurement Parameters
101
Programming Example
101
Step 4: Make a Connection
102
Originating a Connection from the Test Set
102
Originating a Connection from the UE
103
Make a Connection Using Test Mode Commands
103
Step 5: Initiate and Fetch Measurements
104
Initiate a Set of Concurrent Measurements
104
Fetch Measurement Results
104
Step 6: Reconfigure Test Set and UE Connection Parameters
106
Reconfigure the Connection When Using Active Cell
106
Reconfigure the Connection When Using Test Mode
106
Step 7: End the Connection
107
Ending the Connection from the Test Set
107
Ending the Connection from the UE
107
Step 1: Set up the Test Set
108
Description
108
Step 2: Configure Test Set and Mobile Station Parameters
110
Description
110
Step 3: Set Measurement Parameters
114
Description
114
Step 4: Make Connection
119
Description
119
Step 5: Initiate and Fetch Measurements
124
Description
124
Step 6: Reconfigure Test Set and Mobile Station Connection Parameters
129
Description
129
Step 7: End Connection
131
Description
131
Programming an Adjacent Channel Leakage Ratio Measurement
135
Programming Example
135
Returned Values
135
Related Topics
136
Programming an Audio Level Measurement
137
Programming Example
137
Returned Values
137
Related Topics
138
Programming an Audio Frequency Measurement
139
Programming Example
139
Related Topics
139
Programming a Channel Power Measurement
140
Programming Example
140
Returned Values
140
Related Topics
141
Programming a Distortion Measurement
142
Programming Example
142
Returned Values
143
Related Topics
143
Programming a Loopback Bit Error Ratio Measurement
144
Programming Example
144
Returned Values
144
Related Topics
145
Programming a SINAD Measurement
146
Programming Example
146
Returned Values
147
Related Topics
147
Programming a Thermal Power Measurement
148
Programming Example
148
Returned Values
148
Related Topics
149
Programming a Waveform Quality Measurement
150
Programming Example
150
Returned Values
150
Related Topics
151
Preset Descriptions
152
Description
152
Related Topics
154
Receiver Control
155
Manual Versus Automatic Receiver Control
155
Front Panel Access to Receiver Controls
156
Expected Power
156
GPIB Equivalent Commands for Receiver Control
156
Effects on Receiver Control When Changing Operating Mode
157
Related Topics
157
Status Subsystem Overview
158
Description
159
Related Topics
179
Concurrent Measurements
180
Description
180
Concurrent Measurements for the E1963A Test Application
181
Related Topics
182
Measurement Timeouts
183
Description
183
Timeout Values
183
Related Topics
183
Measurement Progress Report
184
Description
184
Programming Example
184
Related Topics
184
Triggering of Measurements
185
Description
185
Related Topics
188
Statistical Measurement Results
189
Description
189
Programming Example
189
Related Topics
189
Integrity Indicator
190
Description
190
Example Program
193
Related Topics
193
Invalid Measurement Results
194
Description
194
Dealing with Semicolon Separated Response Data Lists
195
Description
195
Test System Synchronization Overview
197
Description
197
Commands Used for Synchronization
199
Related Topics
200
Measurement Event Synchronization
201
Description
201
Initiate:done
201
Status:operation:nmrready:fdd
202
Operating Considerations
203
Related Topics
203
Call Processing Event Synchronization
204
Description
204
Related Topics
206
Call Processing State Synchronization
207
Description
207
Related Topics
208
Agilent Technologies 8960 Reference Manual (514 pages)
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 6.31 MB
Table of Contents
Table of Contents
15
Measurements
29
Adjacent Channel Leakage Ratio Measurement Description
30
How Is an Adjacent Channel Leakage Ratio Measurement Made
30
Input Signal Requirements
30
Trigger Source
30
Measurement Calibration
31
Related Topics
31
Audio Level Measurement Description
32
How Is an Audio Level Measurement Made
32
Related Topics
32
Audio Analyzer Measurement Description
33
How Is an Analog Audio Measurement Made
33
De-Emphasis State
34
Expandor Reference Level
34
Trigger Source
34
Related Topics
34
Audio Analyzer Block Diagram
35
Related Topics
35
Audio Frequency Measurement Description
36
Related Topics
36
Channel Power Measurement Description
37
How Is a Channel Power Measurement Made
37
Input Signal Requirements
37
Trigger Source
37
Measurement Calibration
38
Related Topics
38
Distortion Measurement Description
39
How Is a Distortion Measurement Made
39
Related Topics
39
Loopback Bit Error Ratio Measurement Description
40
How Is a Loopback Bit Error Ratio Measurement Made
40
Mobile Station (UE) Control During FDD Test Mode Operation
40
Input Signal Requirements
40
Trigger Source
40
Related Topics
40
SINAD Measurement Description
41
How Is a SINAD Measurement Made
41
Related Topics
41
Thermal Power Measurement Description
42
How Is a Thermal Power Measurement Made
42
Input Signal Requirements
42
Trigger Source
42
Related Topics
42
Waveform Quality Measurement Description
43
How Is a Waveform Quality Measurement Made
43
Input Signal Requirements
43
Trigger Source
43
Measurement Calibration
44
Related Topics
44
Test Adherence to Standards
45
Thermal Power
45
Channel Power
45
Adjacent Channel Leakage Ratio
45
Waveform Quality
45
Frequency Error
45
Loopback Bit Error Ratio
46
Amplitude Offset
47
Description
47
Related Topics
50
Call Processing
51
FDD Test Operating Mode
52
UE (Mobile Station) Control During FDD Test Mode
52
Downlink Channel Settings
53
Noise Sources on the Downlink
54
Other Downlink Signal Settings
54
Uplink Settings
56
Receiver Control Settings
56
Related Topics
56
CW Operating Mode
57
CW Test Mode Operation
57
Related Topics
58
Programming: Getting Started Guide for E1963A W-CDMA Mobile Test Application Revision A.01
59
Introduction
60
Conventions Used in this Getting Started Guide
60
How to Use this Getting Started Guide
60
Useful On-Line Links
61
About the Programming Examples Presented in this Guide
61
Step 1: Set up the Test Set
63
Initialize the Test Set
63
Set up General Operating Conditions
63
Step 2: Configure Test Set and Mobile Station Parameters
64
Set up the Downlink
64
Set up the Uplink
65
Step 3: Set Measurement Parameters
67
Programming Example
67
Step 4: Make a Connection
68
Programming Example
68
Step 5: Initiate and Fetch Measurements
69
Initiate a Set of Concurrent Measurements
69
Fetch Measurement Results
69
Programming Example
69
Step 6: Reconfigure Test Set and Mobile Station Connection Parameters
71
Programming Example
71
Step 7: End the Connection
72
Programming Example
72
Step 1: Set up the Test Set
73
Description
73
Step 2: Configure Test Set and Mobile Station Parameters
75
Description
75
Step 3: Set Measurement Parameters
79
Description
79
Step 4: Make Connection
84
Description
84
Step 5: Initiate and Fetch Measurements
89
Description
89
Step 6: Reconfigure Test Set and Mobile Station Connection Parameters
94
Description
94
Step 7: End Connection
96
Description
96
General Programming
101
Programming an Adjacent Channel Leakage Ratio Measurement
102
Programming Example
102
Returned Values
102
Related Topics
103
Programming an Audio Level Measurement
104
Programming Example
104
Returned Values
104
Related Topics
105
Programming an Audio Frequency Measurement
106
Programming Example
106
Related Topics
106
Programming a Channel Power Measurement
107
Programming Example
107
Returned Values
107
Related Topics
107
Programming a Distortion Measurement
108
Programming Example
108
Returned Values
109
Related Topics
109
Programming a Loopback Bit Error Ratio Measurement
110
Programming Example
110
Returned Values
110
Related Topics
110
Programming a SINAD Measurement
111
Programming Example
111
Returned Values
112
Related Topics
112
Programming a Thermal Power Measurement
113
Programming Example
113
Returned Values
113
Related Topics
113
Programming a Waveform Quality Measurement
114
Programming Example
114
Returned Values
114
Related Topics
115
Preset Descriptions
116
Description
116
Related Topics
118
Receiver Control
119
Manual Versus Automatic Receiver Control
119
Front Panel Access to Receiver Controls
120
Expected Power
120
GPIB Equivalent Commands for Receiver Control
120
Effects on Receiver Control When Changing Operating Mode
121
Related Topics
121
Status Subsystem Overview
122
Description
123
Related Topics
143
Concurrent Measurements
144
Description
144
Concurrent Measurements for the E1963A Test Application
145
Related Topics
145
Measurement Timeouts
146
Description
146
Timeout Values
146
Related Topics
146
Measurement Progress Report
147
Description
147
Programming Example
147
Related Topics
147
Triggering of Measurements
148
Description
148
Related Topics
151
Statistical Measurement Results
152
Description
152
Programming Example
152
Related Topics
152
Integrity Indicator
153
Description
153
Example Program
155
Related Topics
156
Invalid Measurement Results
157
Description
157
Dealing with Semicolon Separated Response Data Lists
158
Description
158
Test System Synchronization Overview
160
Description
160
Commands Used for Synchronization
162
Related Topics
163
Measurement Event Synchronization
164
Description
164
Initiate:done
164
Programming Example
165
Operating Considerations
165
GPIB Commands
167
Diagram Conventions
168
Description
168
Abort Subsystem
170
Description
170
Syntax Diagram and Command Descriptions
170
Abort
171
Afgenerator Subsystem
173
Description
173
Advertisement
Agilent Technologies 8960 Operation Manual (165 pages)
10 Wireless Communications Test Set
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 2.34 MB
Table of Contents
Table of Contents
15
AMPS/136 Mobile Test Application
21
How Do I Make Measurements on a Mobile
22
Establish a Call
22
Select Measurements
23
How Do I Change Measurement Setup
24
Select a Measurement
24
Set up the Measurement
24
How Do I Turn off a Measurement
26
How Do I Change Call Parameters
27
How Do I Change Cell Parameters
28
How Do I Change the MS TX Level
29
Change the Digital MS TX Level Immediately
29
Change the MS TX Level During a Handoff
30
How Do I Perform a Handoff
31
How Do I Configure the Test Set for My Test System
32
Configure Instrument Information and Setup
32
Set Amplitude Offsets
33
Check the Message Log
34
How Do I End a Call
35
AMPS/136 Mobile Measurements
36
Measuring Digital Transmit Power
37
Measuring Modulation Accuracy
38
Measuring Adjacent Channel Power
39
Measuring Bit Error Ratio
40
Measuring IQ Tuning
41
Measuring Analog Transmit Power
43
Measuring Frequency Stability
44
Measuring Frequency Modulation
45
Cdma2000 Mobile Test Application
47
How Do I Make Measurements on a Mobile Station
48
Establish a Call
48
Select Measurements
48
How Do I Change the Measurement Setup
49
Select a Measurement
49
Set up the Measurement
50
How Do I Turn off a Measurement
51
How Do I Set up a Call
52
How Do I Set up an IS-2000 Call
52
How Do I Set up an IS-95 Call
54
How Do I Change Call Parameters
56
How Do I Change Cell Information
57
Set Cell Parameters
57
Set Access Parameters
59
Set Registration Parameters
61
How Do I Change Code Channel Levels
63
How Do I Perform a Handoff
64
How Do I Configure the Test Set for My Test System
65
Configure Instrument Information and Setup
65
Set Amplitude Offsets
66
Check Message Log
67
How Do I End a Call
68
Cdma2000 Measurement Procedures
69
Measuring Waveform Quality
70
Measuring Handoff Waveform Quality
71
Measuring Digital Average Power
72
Measuring Channel Power
73
Measuring Access Probe Power
74
Measuring Frame Error Rate (FER)
76
Measuring TDSO (Test Data Service Option) Frame Error Rate (FER)
77
Measuring Code Domain Power and Code Domain Power + Noise
79
Measuring Code Channel Time/Phase Error
82
Measuring Gated Power
83
Measuring TX Spurious Emissions
84
Related Topics
85
GPRS Mobile Test Application
87
How Do I Make Measurements on a Mobile
88
Establish a Data Connection
88
Select Measurements
89
Agilent Technologies 8960 Manual Operation (91 pages)
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 1.51 MB
Table of Contents
Table of Contents
15
AMPS/136 Mobile Test Application
19
How Do I Make Measurements on a Mobile
20
Establish a Call
20
Select Measurements
21
How Do I Change Measurement Setup
22
Select a Measurement
22
Set up the Measurement
23
How Do I Turn off a Measurement
24
How Do I Change Call Parameters
25
How Do I Change the MS TX Level
26
Change the Digital MS TX Level Immediately
26
Change the MS TX Level During a Handoff
27
How Do I Perform a Handoff
28
How Do I Configure the Test Set for My Test System
29
Configure Instrument Information and Setup
29
Set Amplitude Offsets
30
Check the Message Log
31
How Do I End a Call
32
Cdma2000/Is-2000 Mobile Test Application
33
How Do I Make Measurements on a Mobile
34
Establish a Call
34
Select Measurements
35
How Do I View a Graphical Measurement
36
How Do I Change the Measurement Setup
37
Select a Measurement
37
Set up the Measurement
38
How Do I Turn off a Measurement
39
How Do I Set up a Call
40
How Do I Change Call Parameters
42
How Do I Change Cell Information
43
Set Cell Parameters
43
Select the Cell Parameters Menu
43
Set a Cell Parameter
44
Set Access Parameters
45
Select the Access Parameters Menu
45
Set an Access Parameter
46
Set Registration Parameters
47
Select the Registration Parameters Menu
47
Set a Registration Parameter
48
How Do I Change Code Channel Levels
49
How Do I Perform a Handoff
50
How Do I Configure the Test Set for My Test System
51
Configure Instrument Information and Setup
51
Set Amplitude Offsets
52
Check Message Log
53
How Do I End a Call
54
GPRS Mobile Test Application
55
How Do I Make Measurements on a Mobile
56
Establish a Data Connection
56
Agilent Technologies 8960 Programming Manual (72 pages)
Wireless Comm Test Set
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 0.54 MB
Table of Contents
Table of Contents
11
Conventions Used in this Programming Guide
14
Purpose of this Programming Guide
14
How this Programming Guide Is Organized
14
How to Use this Programming Guide
16
About the Programming Examples Presented in this Programming Guide
16
Step 1: Set the Test Set's Operating Mode to Active Cell
17
Background
17
Overview of Active Cell Operating Mode
17
Setting the Test Set's Operating Mode to Active Cell
18
Step 2: Configure the Base Station Emulator (BSE)
19
Background
19
Configuring the Broadcast Channel Parameters
20
Configuring the Traffic Channel Parameters
22
Things that Can Go Wrong
23
Step 3: Configure the Measurement Execution Parameters
24
Background
24
Overview
25
Configuring Measurement Averaging Parameters
26
Configuring Measurement Triggering Parameters
27
Configuring the Burst Synchronization Parameter
28
Configuring Measurement Timeout Parameters
29
Configuring Measurement Specific Parameters
30
Step 4: Establish an Active Link with Mobile Station
32
Background
32
Overview
36
Process for Making a Base Station Originated Call
36
Process for Making a Mobile Station Originated Call
39
Step 5: Set the Mobile Station's Operating Conditions
42
Overview
42
Step 6: Make Measurements
43
Background
43
Things that Can Go Wrong
46
Step 6A: Start Set of Concurrent Measurements
47
Starting Measurements
47
Step 6B: Determine if a Measurement Is Done
49
Background
49
Overview
49
Step 6C: Obtain a Set of Measurement Results
51
Background
51
Overview
52
Step 7: Perform an Intra-Cell Handover
53
Background
53
Performing an Intra-Cell Handover
53
Performing a Dual-Band Handover
54
Step 8: Disconnect the Mobile Station from the BSE
57
Background
57
Overview
58
Terminating an Active Call from the Base Station Emulator
58
Terminating an Active Call from the Mobile Station
59
Comprehensive Program Example
63
Example Program with Comments
64
Example Program Without Comments
69
Agilent Technologies 8960 Manual (42 pages)
Analog Generator Level Accuracy
Brand:
Agilent Technologies
| Category:
Inverter
| Size: 0.95 MB
Agilent Technologies 8960 Installation Note (30 pages)
Wireless Communication Test Set, Adds CDMA2000, WCDMA and 1xEV capability to the E5515B , Kit
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 0.57 MB
Table of Contents
Installation Kit Parts List
2
Tools Required
3
Safety Considerations
3
Replace Covers
8
Agilent Technologies 8960 Installation Note (4 pages)
MDC Upgrade for E5515B/C. Kit Part Number: E5515BU-506 and E5515CU-506
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 0.04 MB
Advertisement
Related Products
Agilent Technologies 8935 Series
Agilent Technologies 8922M
Agilent Technologies 8922S
Agilent Technologies 8920B
Agilent Technologies 8960 Series 10
Agilent Technologies 8922
Agilent Technologies 89601A
Agilent Technologies 89607A
Agilent Technologies 8924C
Agilent Technologies 85056D
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL