Agilent Technologies ENA Series User Manual page 722

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Softkey Functions
Sweep Setup Menu
Key Operation
(Continued)
Sweep Type
Returns to the softkey display screen one level higher.
Cancel
Displays the segment sweep setup table as well as softkeys for editing the segment table.
Edit Segment Table
Alternates the setup mode for the sweep range between two methods: one
Freq Mode
using the starting and ending frequencies (
the center frequency and a frequency span (
Enables or disables the IF bandwidth display in the segment table.
List IFBW
Enables or disables the power level display in the segment table.
List Power
Enables or disables the segment delay display in the segment table.
List Delay
Enables or disables the segment sweep mode display in the segment table.
List Sweep Mode
Enables or disables the segment sweep time display in the segment table.
List Time
Deletes from the segment table the segment upon which the cursor is
Delete
currently located. If the cursor is not displayed, the segment on the bottom
will be deleted.
Adds a new segment immediately above the segment upon which the cursor
Add
is currently located. If the cursor is not displayed, a new segment will be
added to the bottom of the table.
Displays softkeys for clearing elements of the segment table.
Clear Segment
Table
Deletes all segments in the segment table.
OK
Returns to the softkey display screen one level higher.
Cancel
Exports (saves data in file formats used by other software) the segment
Export to CSV File
table as a CSV (comma-separated value) file.
Imports (loads a file that is written in a format used by other software) a
Import from CSV
CSV (comma-separated value) file to the segment table of
File
E5070B/E5071B.
Returns to the softkey display screen one level higher.
Return
Selects linear frequency (
Segment Display
(1, 2, ..., N; where N refers to the number of points) (
drawing the X-axis of a rectangular display format in a segment sweep.
Displays the softkey to setup the frequency offset.
Frequency Offset
Turns on/off of the frequency offset feature.
Frequency Offset
Displays the softkey to setup the frequency offset parameter for test port 1.
Port 1
Multiplier
Set the muliplier of the base frequency
Divisor
Set the divisor of the base frequency
Offset
Set the offset for the base frequency
Set the start frequency.
Start
Set the stop frequency.
Stop
Returns to the softkey display screen one level higher.
Return
Displays the softkey to setup the frequency offset parameters for test port 2 to 4. Lower level softkeys are the same
Port 2
to
as the
Port 1
Port 4
Displays the softkey to setup the external signal source.
External Source
Set the external signal source frequency.
LO Frequency
Multiplier
Set the muliplier of the base frequency
Divisor
Set the divisor of the base frequency
716
Function
Start/Stop
Center/Span
) or selects the order of measurements
Freq Base
*2
.
*2
.
*2
.
.
*2
.
*2
.
:SENS{1-16}:SEGM:DATA
), and the other using
).
:SENS{1-16}:SEGM:DATA
:SENS{1-16}:SEGM:DATA
:SENS{1-16}:SEGM:DATA
:SENS{1-16}:SEGM:DATA
:SENS{1-16}:SEGM:DATA
:SENS{1-16}:SEGM:DATA
:SENS{1-16}:SEGM:DATA
None
:MMEM:STOR:SEGM
:MMEM:LOAD:SEGM
:DISP:WIND{1-16}:X:SPAC LIN
:DISP:WIND{1-16}:X:SPAC OBAS
) for
Order Base
:SENS{1-16}:OFFS
:SENS{1-16}:OFFS:PORT{1-4}:MULT
:SENS{1-16}:OFFS:PORT{1-4}:DIV
:SENS{1-16}:OFFS:PORT{1-4}:OFFS
:SENS{1-16}:OFFS:PORT{1-4}:STAR
:SENS{1-16}:OFFS:PORT{1-4}:STOP
:SENS{1-16}:OFFS:LOC:STAT
:SENS{1-16}:OFFS:LOC:MULT
:SENS{1-16}:OFFS:LOC:DIV
SCPI Command
Appendix D

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5070bE5071b

Table of Contents