Key Operation
(Continued)
Transform
Displays softkeys for selecting a type of the window.
Window
Selects the maximum type.
Maximum
Selects the normal type.
Normal
Selects the minimum type.
Minimum
Displays softkeys for setting up the user window shape.
User
Sets the impulse width value.
Impulse Width
Sets the rise time of the step signal.
Rise Time
Sets the b value of Kaiser Bessel window.
Kaiser Beta
Returns to the softkey display screen one level higher.
Return
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the conversion function.
Conversion
Enables or disables the conversion function.
Conversion
Displays softkeys for selecting a converted parameter.
Function
Selects the equivalent impedance in reflection measurement.
Z:Reflection
Selects the equivalent impedance in transmission measurement.
Z:Transmission
Selects the equivalent impedance in transmission-shunt measurement.
Z:Trans-Shunt
Selects the equivalent admittance in reflection measurement.
Y:Reflection
Selects the equivalent admittance in transmission measurement.
Y:Transmission
Selects the equivalent admittance in transmission-shunt measurement.
Y:Trans-Shunt
Selects the inverse S-parameter.
1/S
Selects the conjugation.
Conjugation
Returns to the softkey display screen one level higher.
Cancel
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the limit test function.
Limit Test
Enables or disables the limit test function.
Limit Test
Enables or disables the limit line display.
Limit Line
Displays softkeys for editing the limit line.
Edit Limit Line
Deletes the line at the cursor from the limit table.
Delete
Adds a new segment to the limit table under the line on which the cursor is
Add
located.
Displays softkeys for clearing the contents of the limit table.
Clear Limit Table
Deletes all segments in the limit table.
OK
Returns to the softkey display screen one level higher.
Cancel
Exports (saves the data in formats used by other software) the limit table to
Export to CSV
a CSV (comma-separated value) file.
File
Imports (loads the data from files in different formats) a CSV
Import from CSV
(comma-separated value) file to the limit table.
File
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the limit line offset function.
Limit Line Offset
Sets the stimulus offsets.
Stimulus Offset
Sets the amplitude offsets.
Amplitude
Offset
Appendix D
Function
Softkey Functions
Analysis Menu
SCPI Command
:CALC{1-16}:TRAN:TIME KBES 13
:CALC{1-16}:TRAN:TIME KBES 6
:CALC{1-16}:TRAN:TIME KBES 0
:CALC{1-16}:TRAN:TIME IMP:WIDT
:CALC{1-16}:TRAN:TIME STEP:RTIM
:CALC{1-16}:TRAN:TIME KBES
:CALC{1-16}:CONV
:CALC{1-16}:CONV:FUNC ZREF
:CALC{1-16}:CONV:FUNC ZTR
:CALC{1-16}:CONV:FUNC ZTSH
:CALC{1-16}:CONV:FUNC YREF
:CALC{1-16}:CONV:FUNC YTR
:CALC{1-16}:CONV:FUNC YTSH
:CALC{1-16}:CONV:FUNC INV
:CALC{1-16}:CONV:FUNC CONJ
:CALC{1-16}:LIM
:CALC{1-16}:LIM:DISP
:CALC{1-16}:LIM:DATA
:CALC{1-16}:LIM:DATA
:CALC{1-16}:LIM:DATA
:CALC{1-16}:LIM:DATA
:MMEM:STOR:LIM
:MMEM:LOAD:LIM
:CALC{1-16}:LIM:OFFS:STIM
:CALC{1-16}:LIM:OFFS:AMPL
659