Displays the softkey to execute a scalar-mixer calibration.
Mixer/Converter
Calibration
Displays the softkey to execute a scalar-mixer calibration by using the calibration kits.
Scalar Cal (Manual)
Displays the softkey to select test ports and calibration methods you want to use.
Select Ports
Select 1-port calibration for the test port 1.
Port 1
:
*2
Select 1-port calibration for the test port 4.
Port 4
Select a scalar-mixer calibration for test port 1→2 (forward).
2-1 (fwd)
Select a scalar-mixer calibration for test port 2→1 (reverse).
1-2 (rev)
Select a scalar-mixer calibration for test port 1→2 and 2→1 (both
2,1 (both)
directions).
:
Select a scalar-mixer calibration for test port 3→4 (forward).
*2
4-3 (fwd)
*2
Select a scalar-mixer calibration for test port 4→3 (reverse).
3-4 (rev)
Select a scalar-mixer calibration for test port 3→4 and 4→3 (both
*2
3,4 (both)
directions).
Returns to the softkey display in one level higher.
Cancel
Displays the softkey to execute standard (OPEN, SHORT, and LOAD) measurements.
Reflection
Executes an OPEN reflection calibration on test port x by using the
Port x @
Freq x
frequency that is set in test port x. The x changes by the selected
[Open]
test port and calibration method.
Executes an OPEN reflection calibration on test port x by using the
Port x @
frequency that is set in test port y. The x and y change by the
Freq y
[Open]
selected test port and calibration method.
Executes a SHORT reflection calibration on test port x by using the
Port x @
Freq x
frequency that is set in test port x. The x changes by the selected
[Short]
test port and calibration method.
Executes a SHORT reflection calibration on test port x by using the
Port x @
Freq y
frequency that is set in test port y. The x and y change by the
[Short]
selected test port and calibration method.
Executes a LOAD reflection calibration on test port x by using the
Port x @
Freq x
frequency that is set in test port x. The x changes by the selected
[Broadband]
test port and calibration method.
Executes a LOAD reflection calibration on test port x by using the
Port x @
Freq y
frequency that is set in test port y. The x and y change by the
[Broadband]
selected test port and calibration method.
:
Returns to the softkey display in one level higher.
Return
Appendix D
Function
:
:
:
Softkey Functions
Calibration Menu
SCPI Command
:SENS{1-16}:CORR:OFFS:COLL:METH:
SOLT1
:
:SENS{1-16}:CORR:OFFS:COLL:METH:
SOLT1
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:SENS{1-16}:CORR:OFFS:COLL:OPEN
:SENS{1-16}:CORR:OFFS:COLL:OPEN
:SENS{1-16}:CORR:OFFS:COLL:SHOR
:SENS{1-16}:CORR:OFFS:COLL:SHOR
:SENS{1-16}:CORR:OFFS:COLL:LOAD
:SENS{1-16}:CORR:OFFS:COLL:LOAD
:
685