Fixture Simulator
De-Embedding S4P
Topology
Ports
*2
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
3-2-4
test ports 3, 2, and 4, respectively.
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
*2
3-4-1
test ports 3, 4, and 1, respectively.
*2
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
3-4-2
test ports 3, 4, and 2, respectively.
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
*2
4-1-2
test ports 4, 1, and 2, respectively.
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
*2
4-1-3
test ports 4, 1, and 3, respectively.
*2
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
4-2-1
test ports 4, 2, and 1, respectively.
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
*2
4-2-3
test ports 4, 2, and 3, respectively.
*2
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
4-3-1
test ports 4, 3, and 1, respectively.
Sets the ports of the analyzer connected to ports a, b, and c in Figure 7-6 to
*2
4-3-2
test ports 4, 3, and 2, respectively.
Returns to the softkey display screen one level higher.
Cancel
Displays the softkey to select a port of the analyzer (test port) that you want to connect to the DUT. (When you
*2
Ports
select
A
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
1-2-3-4
to test ports 1, 2, 3, and 4, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
1-2-4-3
to test ports 1, 2, 4, and 3, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
1-3-2-4
to test ports 1, 3, 2, and 4, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
1-3-4-2
to test ports 1, 3, 4, and 2, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
1-4-2-3
to test ports 1, 4, 2, and 3, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
1-4-3-2
to test ports 1, 4, 3, and 2, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
2-1-3-4
to test ports 2, 1, 3, and 4, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
2-1-4-3
to test ports 2, 1, 4, and 3, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
2-3-1-4
to test ports 2, 3, 1, and 4, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
2-3-4-1
to test ports 2, 3, 4, and 1, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
2-4-1-3
to test ports 2, 4, 1, and 3, respectively.
Sets the ports of the analyzer connected to ports a, b, c and d in Figure 7-6
2-4-3-1
to test ports 2, 4, 3, and 1, respectively.
656
Function
on the
menu.)
Select Topology
SCPI Command
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
3,2,4
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
3,4,1
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
3,4,2
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
4,1,2
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
4,1,3
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
4,2,1
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
4,2,3
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
4,3,1
:CALC{1-16}:FSIM:EMB:TOP:B:PORT
4,3,2
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 1,2,3,4
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 1,2,4,3
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 1,3,2,4
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 1,3,4,2
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 1,4,2,3
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 1,4,3,2
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 2,1,3,4
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 2,1,4,3
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 2,3,1,4
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 2,3,4,1
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 2,4,1,3
:CALC{1-16}:FSIM:EMB:TOP:C:POR
T 2,4,3,1