Softkey Functions
Calibration Menu
Key Operation
(Continued)
Mixer/Converter
Calibration
Scalar Cal (Manual)
Displays the softkey to execute THRU standard measurements.
Transmission
Executes a THRU calibration on test ports x and y by using the
Thru x-y @
Freq x
frequency that is set in test port x. The x and y change by the
[Thru]
selected test port and calibration method.
Executes a THRU calibration on test ports y and x by using the
Thru y-x @
Freq y
frequency that is set in test port y. The x and y change by the
[Thru]
selected test port and calibration method.
Returns to the softkey display in one level higher.
Return
Displays the softkey to execute a power calibration.
Power Meter
Selects the channel of the power sensor you want to use for the
Use Sensor
measurement of power calibration data.
Executes a power calibration on test port x by using the frequency
Port x @
that is set in test port x. The x changes by the selected test port and
Freq x
calibration method.
Executes a power calibration on test port x by using the frequency
Port x @
that is set in test port y. The x and y change by the selected test port
Freq y
and calibration method.
Executes a power calibration on test port y by using the frequency
Port y @
that is set in test port x. The x and y change by the selected test port
Freq x
and calibration method.
Executes a power calibration on test port y by using the frequency
Port y @
that is set in test port y. The y changes by the selected test port and
Freq y
calibration method.
Returns to the softkey display in one level higher.
Return
Terminates a calibration process and calculates the calibration
Done
coefficients.
Displays the softkey to cancel a calibration.
Cancel
Cancels a calibration process and clear the measurement data of
OK
standard.
Returns to the softkey display in one level higher.
Cancel
Returns to the softkey display in one level higher.
Return
Displays the softkey to execute a scalar-mixer calibration by using the ECal.
Scalar Cal (ECal)
Displays the softkey to select test ports and calibration methods you want to use for scalar-mixer calibration.
Select Ports
Select 1-port calibration for the test port 1.
Port 1
:
Select 1-port calibration for the test port 4.
*2
Port 4
Select a scalar-mixer calibration for test port 1→2 (forward).
2-1 (fwd)
Select a scalar-mixer calibration for test port 2→1 (reverse).
1-2 (rev)
Select a scalar-mixer calibration for test port 1→2 and 2→1 (both
2,1 (both)
directions).
:
Select a scalar-mixer calibration for test port 3→4 (forward).
*2
4-3 (fwd)
Select a scalar-mixer calibration for test port 4→3 (reverse).
*2
3-4 (rev)
686
Function
:
:
SCPI Command
:SENS{1-16}:CORR:OFFS:COLL:THRU
:SENS{1-16}:CORR:OFFS:COLL:THRU
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:SAVE
:SENS{1-16}:CORR:OFFS:COLL:CLE
None
:
None
None
None
None
:
None
None