Agilent Technologies ENA Series User Manual page 693

Rf network analyzers
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Key Operation
(Continued)
Mixer/Converter
Calibration
Scalar Cal (ECal)
Select Ports
Select a scalar-mixer calibration for test port 3→4 and 4→3 (both
*2
3,4 (both)
directions).
Returns to the softkey display in one level higher.
Cancel
Displays the softkey to execute a power calibration.
Power Meter
Selects the channel of the power sensor you want to use for the
Use Sensor
measurement of power calibration data.
Executes a power calibration on test port x by using the frequency
Port x @
that is set in test port x. The x changes by the selected test port and
Freq x
calibration method.
Executes a power calibration on test port x by using the frequency
Port x @
that is set in test port y. The x and y change by the selected test port
Freq y
and calibration method.
Executes a power calibration on test port y by using the frequency
Port y @
that is set in test port x. The x and y change by the selected test port
Freq x
and calibration method.
Executes a power calibration on test port y by using the frequency
Port y @
that is set in test port y. The y changes by the selected test port and
Freq y
calibration method.
Returns to the softkey display one level higher.
Return
Executes a scalar-mixer calibration and calculates the calibration
ECal & Done
coefficient. The GPIB command and parameter change by the
selected test port and calibration method.
Displays the softkey to cancel a calibration.
Cancel
Cancels a calibration process and clear the measurement data of
OK
standard.
Returns to the softkey display one level higher.
Cancel
Returns to the softkey display one level higher.
Return
Displays the softkey that clears the scalar-mixer calibration coefficient.
Clear
Clears the scalar-mixer calibration coefficient.
OK
Returns to the softkey display screen one level higher.
Cancel
Returns to the softkey display screen one level higher.
Return
Displays the softkey to set the trigger source for calibration.
Cal Trig Source
Sets the trigger source at calibration to "Internal".
Internal
Sets the trigger source at calibration to the same trigger source
System
setting used when measurement is made.
Returns to the "E5070B/E5071B Menu (Top Menu)" on page 646.
Return
*1. Only with Options 313, 314, 413, and 414.
*2. Only with Options 413 and 414.
Appendix D
Function
Softkey Functions
Calibration Menu
SCPI Command
None
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:PMET
:SENS{1-16}:CORR:OFFS:COLL:SMIX2
:SENS{1-16}:CORR:OFFS:COLL:SOLT1
:SENS{1-16}:CORR:OFFS:COLL:CLE
:SENS{1-16}:CORR:OFFS:CLE
:SENS{1-16}:CORR:TRIG:SOUR:FREE ON
:SENS{1-16}:CORR:TRIG:SOUR:FREE OFF