SROS Command Line Interface Reference Guide
test-pattern [clear | errors | insert | ones | p215 | p220 | p511 | qrss |
zeros]
Use the test-pattern command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the no form of this command to cease pattern generation.
Syntax Description
clear
errors
insert
ones
p215
p220
p511
qrss
zeros
Default Values
No defaults necessary for this command.
Usage Examples
The following example activates the pattern generator for a stream of continuous ones:
ProCurve(config)#interface t1 1/1
ProCurve(config-t1 1/1)#test-pattern ones
5991-2114
Clears the test pattern error count. Display the error count using the errors
keyword.
Displays the test pattern error count.
Inserts an error into the currently active test pattern. Display the error count using
the errors keyword.
Generates a test pattern of continous ones.
Generates a pseudorandom test pattern sequence based on a 15-bit shift
register.
Generates a pseudorandom test pattern sequence based on a 20-bit shift
register.
Generates a repeating test pattern of ones and zeros.
Generates a random test pattern of ones and zeroes.
Generates a test pattern of continous zeros.
© Copyright 2006 Hewlett-Packard Development Company, L.P.
T1 Interface Configuration Command Set
713