Show Inlinepower (Stack) - Dell Force10 S2410-01-10GE-24P Command Reference Manual

Sftos command reference
Hide thumbs Also See for Force10 S2410-01-10GE-24P:
Table of Contents

Advertisement

Parameters
type-string
Defaults
no description
Mode
Interface Config; Interface Range Ethernet
Command
Version 2.5.1
History
Related

show inlinepower (stack)

Commands
show inlinepower
show inlinepower (stack)
This command shows the status for all switches in a stack that support PoE.
show inlinepower
Syntax
Command Modes
User Exec; Privileged Exec
Command
Version 2.5.1
History
Example
Figure 6-37. Example Output of show inlinepower Command for a Stack
Force10-S50V >show inlinepower
Unit
----
Table 6-17 defines the fields displayed in
Table 6-17. show interfaces description Command Example Fields
Field
Unit
Status
Power(W)
Consumption(W)
Usage(%)
Threshold(%)
Trap
Related
inlinepower
Commands
Enter an alphanumeric description.
Introduced
Introduced
Status
Power(W)
------
--------
1
Auto
360
Description
The stack member IDs
Whether PoE from the switch is enabled ("Auto") or disabled (Off)
The total PoE power budget in watts allotted for the switch
The current PoE power usage in watts for the switch
The percentage of PoE power used by the switch of the allotted amount
The allotted percentage of the power that could be made available
Whether PoE SNMP traps are enabled or disabled
Display PoE status of stack members.
Display PoE status of designated port.
Consumption(W)
Usage(%)
--------------
--------
22
6.11
Figure
6-37.
Enable or disable PoE for the switch.
Threshold(%)
Trap
------------
----
100
enable
System Configuration Commands | 117