Dell Force10 S2410-01-10GE-24P Command Reference Manual page 262

Sftos command reference
Hide thumbs Also See for Force10 S2410-01-10GE-24P:
Table of Contents

Advertisement

Parameters
Defaults
Mode
Command
History
Usage
|
RMON Commands
262
1-65535
An integer, from 1 to 65535 that uniquely identifies the alarm in the RMON Alarm
Table.
SNMP_OID
The MIB object to monitor. The variable must be in the SNMP OID format, for
example, 1.3.6.1.2.1.1.3.
For general MIB queries, the OIDs start from 1.3.6.1.2.1. For private MIB queries,
the OIDs start from 1.3.6.1.4.1.6027.1, where 6027 is the Dell Force10 Enterprise
Number.
The object type must be a 32-bit integer.
5-3600
Sample interval, in seconds, with which the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON Alarm table.
Range: 5 to 3600 seconds
delta
Enter the keyword
alarmSampleType in the RMON Alarm table.
absolute
Enter the keyword
alarmSampleType in the RMON Alarm table.
rising-threshold
Enter the keyword
the rising-threshold alarm is either triggered or reset — the minimum
0-4294967295 index
threshold for causing a rising alarm.
Range: 0-4294967295
Then, in place of
the rising threshold exceeds its limit. This value is the same as the
alarmRisingEventIndex or alarmTable of the RMON MIB. If there is no
corresponding rising-threshold event, the value is zero.
Range: 0-65535
falling-threshold
Enter the keyword
falling-threshold alarm is either triggered or reset — the maximum threshold
0-4294967295 index
for causing a falling alarm.
Range: 0-4294967295
Then enter the event number to trigger (0-65535) when the falling threshold
exceeds its limit. This value is the same as the alarmFallingEventIndex or
the alarmTable of the RMON MIB. If there is no corresponding
falling-threshold event, the value is zero.
Range: 0-65535
owner
string
(OPTIONAL) Enter the keyword
for the alarm. This is the alarmOwner object in the alarmTable of the RMON MIB.
Range: string of 127 characters maximum
owner
Global Config
Version 2.5.1.0
Introduced
A pair relationship exists between the
falling-threshold
index
and
For example, the following command sequence requires that RMON event 10 be triggered by RMON
alarm 50 when the rising threshold of 200 is exceeded. RMON event 20 will be triggered by RMON
alarm 50 when the falling threshold of 100 is passed.
delta
to test the change between MIB variables. This is the
absolute
to test each MIB variable directly. This is the
rising-threshold
event-number,
falling-threshold
numbers entered here in rising-threshold
index
index
numbers defined by the command
followed by the value (32-bit) at which
enter the event number to trigger when
followed by the value (32-bit) the
owner
followed by a name to specify an owner
rmon event
index.
index
and