Example
Report Fields
|
Stacking Commands
222
shows the output of both show switch and show switch
Figure 12-79
Figure 12-79. Example of Output from the show switch Command on an S50V
Force10-S50V>show switch
Management
Switch
Status
------ ------------ ---------------- ---------------- --------------- --------
1
Mgmt Switch
S50-01-GE-48T-V
Force10 #show switch ?
<cr>
<unit>
Force10-S50V>show switch 1
Switch............................ 1
Management Status................. Management Switch
Hardware Management Preference.... Unassigned
Admin Management Preference....... Unassigned
Switch Type....................... 0xe5040002
Preconfigured Model Identifier.... S50-01-GE-48T-V
Plugged-in Model Identifier....... S50-01-GE-48T-V
Switch Status..................... OK
Switch Description................ Force10 S50V - 48 GE, 4 TENGIG POE
Expected Code Type................ 0x100b000
Detected Code Version............. 2.5.1
Detected Code in Flash............ 2.5.1
Serial Number..................... DEF634014
Up Time........................... 4 days 19 hrs 32 mins 13 secs
When a unit is not specified, the fields displayed are the following:
Switch—This field displays the unit identifier assigned to the switch.
Management Status—This field indicates whether the switch is the management unit, a stack member,
or the status is unassigned.
Preconfigured Model Identifier—This field displays the model identifier of a preconfigured switch ready
to join the stack. The Model Identifier is a 32-character field assigned by the device manufacturer to
identify the device.
Plugged-In Model Identifier—This field displays the model identifier of the switch in the stack. Model
Identifier is a 32-character field assigned by the device manufacturer to identify the device.
Switch Status—This field indicates the switch status. Possible values for this state are: OK, Unsup
ported, CodeMismatch, ConfigMismatch, or NotPresent.
Code Version—This field indicates the detected version of code on this switch.
When a unit is specified, the fields displayed are the following:
Switch—This field displays the unit identifier assigned to the switch.
Management Status—This field indicates whether the switch is the management unit a, stack member,
or the status is unassigned.
Hardware Management Preference—This field indicates the hardware management preference of the
switch. The hardware management preference can be disabled or unassigned.
Admin Management Preference—This field indicates the administrative management preference value
assigned to the switch. This preference value indicates how likely the switch is to be chosen as the
management unit.
Switch Type—This field displays the 32-bit numeric switch type.
Preconfig
Plugged-in
Model ID
Model ID
S50-01-GE-48T-V
Press enter to execute the command.
Enter switch ID in the range of 1 to 8.
unit-id
for on an S50V.
Switch
Code
Status
Version
OK
2.5.1.1