062-211 IIT/IPS PWB EEPROM RAP
BSD-ON: 3.1
The IPS EEPROM failed during the Read/Write operation.
Procedure
Check the connection of each IIT/IPS PWB connector. The connectors are securely con-
nected.
Y
N
Connect the connectors.
Switch on the power. The problem persists.
Y
N
Return to Service Call Procedures
Replace the IIT/IPS PWB
(PL
11.3).
Launch Version
WorkCentre 5225, 5230
062-277 IIT/IPS PWB DADF PWB Communication RAP
BSD-ON: 3.5
Transmission error occurred between the IIT/IPS PWB and the DADF PWB.
Procedure
Check the connection of each IIT/IPS PWB connector. The connectors are securely con-
nected.
Y
N
Connect the connectors.
Check the connection of each DADF PWB connector. The connectors are securely con-
nected.
Y
N
Connect the connectors.
Check the wire between
P/J751
cuit or a short circuit (BSD 3.5
P/J752
and
P750
are conducting without an open circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Replace the IIT/IPS PWB
(PL
If the problem persists, replace the DADF PWB
February, 2008
2-511
and P750, and between
P/J752
and
Flag
1). The wires between
P/J751
and P750, and between
11.3).
(PL
15.3).
062-211, 062-277
P750
for an open cir-
Status Indicator Raps