Ospf Restart Grace-Period - Allied Telesis AR2050V Command Reference Manual

Secure, for alliedware plus version 5.4.7-1.x
Table of Contents

Advertisement

OSPF C
OMMANDS
-
OSPF RESTART GRACE
PERIOD

ospf restart grace-period

Overview
Use this command to configure the grace-period for restarting OSPF routing.
Use the no variant of this command to revert to the default grace-period.
Syntax
ospf restart grace-period <1-1800>
no ospf restart grace-period
Default
In the AlliedWare Plus™ OSPF implementation, the default OSPF grace-period is
180 seconds.
Mode
Global Configuration
Usage
Use this command to enable the OSPF Graceful Restart feature and set the restart
grace-period. Changes from the default restart grace-period are displayed in the
running- config. The restart grace-period is not displayed in the running-config if
it has been reset to the default using the no variant of this command.
Example
To set the OSPF restart grace-period to 250 seconds, use the commands:
awplus#
awplus(config)#
To reset the OSPF restart grace-period to the default (180 seconds), use the
commands:
awplus#
awplus(config)#
Validation
show running-config
Commands
Related
ospf restart helper
Commands
restart ospf graceful
C613-50186-01 Rev B
Parameter
Description
<1-1800>
Specifies the grace period in seconds.
configure terminal
ospf restart grace-period 250
configure terminal
no ospf restart grace-period
Command Reference for AR2050V
AlliedWare Plus™ Operating System - Version 5.4.7-1.x