Blown Fuse Conditions; Power Supply Unit - Ricoh D037 Service Manual

Hide thumbs Also See for D037:
Table of Contents

Advertisement

Electrical Component Defects
Sensor Name/
No.
Sensor Board Name

8.1.2 BLOWN FUSE CONDITIONS

Power Supply Unit

Fuse
115V
FU101
15A/125V
FU102
10A/125V
FU103
2A/250V
FU4
5A/250V
FU5
5A/250V
FU6
5A/250V
FU7
10A/125V
FU8
10A/125V
FU9
6.3A/125V
For continued protection against risk of fire, replace only with same type and rating
of fuse.
D037/D038/D040/D041
Active
Rating
220V - 240V
The i-controller works, but SC547 is issued. (5V
8A/250V
power to the fusing unit is not supplied.)
No response. (5V power to the PSU is not
5A/250V
supplied.)
5V power to the scanner heater and tray heater is
2A/250V
not supplied.
5V power to the i-controller and BCU is not
5A/250V
supplied.
5A/250V
5V power to the BCU is not supplied.
5A/125V
5VS power to the i-controller is not supplied.
10A/125V
24VS power to the BCU is not supplied.
10A/125V
24VS power to the BCU is not supplied.
24V power to the DRB and i-controller is not
6.3A/125V
supplied.
CN
Condition
Shorted
Symptom when turning on the main switch
8-6
Symptom
"Open cover" cannot be
detected.
SM Appendix

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D037 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF