Center Temp. 1: 226–
010 Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
Ends Temp. 1: 226–
011 Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
Center Temp. 2: 226–
012 Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
Ends Temp. 2: 226–
013 Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
Center Temp. 3: –226
014 Specifies the temperature correction for the heating roller (center) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-020.
Ends Temp. 3: –226
015 Specifies the temperature correction for the heating roller (ends) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-020.
Center Temp. 4: –226
016 Specifies the temperature correction for the heating roller (center) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
SM Appendix
ENG
[-10 / 10 / 0 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
[-10 to 10 / -5 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
9-15