2.
Disconnect the connector [A].
3.
Heating roller thermistor assembly [B] (
4.
Heating roller thermistor [A] (
Cleaning Requirement
The heating roller thermistor requires cleaning maintenance at every 60 K interval. Clean
the heating roller thermistor with a dry cloth.
4.11.13 PRESSURE ROLLER THERMISTOR
Pressure Roller Thermistor: Center
1.
Fusing unit (
Section: Fusing Unit)
2.
Fusing upper cover (
SM
x 1)
x 1)
Section: Pressure Roller Fusing Lamp)
4-95
Fusing
D037/D038/D040/D041