System Service Mode
Pressure Ready Temp
007 Sets the heating roller offset temperature at the end of the heating roller. This
value is one of the thresholds to determine if the machine is at the heating
roller target temperature during warm-up.
010 Stand-By: Center
011 Stand-By: End
Stand-By:P-Roller
012 Sets the pressure roller offset temperature. This value is one of the thresholds
to determine if the machine is at the heating roller target temperature during
warm-up.
013 Panel Off Mode: Center
014 Panel Off Mode: Ends
015 Panel Off Mode: P-Roller
016 Low Power: Center
017 Low Power: Ends
018 Low Power: P-Roller
019 Off Mode: Center
020 Off Mode: Ends
021 Off Mode:P-Roller
030 Plain:FC:Simplex:Center
031 Plain: FC: Simplex: Ends
032 Plain:FC:Duplex:Center
033 Plain: FC: Duplex: Ends
034 Plain: BW: Simplex:Center
035 Plain: BW: Simplex: Ends
D037/D038/D040/D041
*ENG
[0 to 150 / 20 / 1 deg/step]
* ENG
[140 to 170 / 160 / 1 deg/step]
* ENG
[140 to 170 / 165 / 1 deg/step]
* ENG
[135 to 165 / 155 / 1 deg/step]
* ENG
[100 to 150 / 130 / 1 deg /step]
* ENG
[100 to 150 / 130 / 1 deg /step]
*ENG
[135 to 165 / 150 / 1 deg /step]
*ENG
[30 to 100 / 40 / 1 deg /step]
*ENG
*ENG
[30 to 155 / 100 / 1 deg /step]
*ENG
[0 to 180 / 0 / 1 deg /step]
*ENG
*ENG
[0 to 170 / 0 / 1 deg /step]
*ENG
[125 to 175 / 145 / 1 deg /step]
*ENG
*ENG
*ENG
*ENG
*ENG
9-6