Ricoh D037 Service Manual page 585

Hide thumbs Also See for D037:
Table of Contents

Advertisement

Page: Standby: FC
Adjusts the threshold of the line position adjustment for BW printing mode in
007
stand-by mode. The line position adjustment is done when the number of
outputs in color printing mode reaches the value specified with this SP and the
condition of SP2-193-008 or SP2-193-009 is satisfied.
Temp Change
008 Adjust the temperature change threshold for the line position adjustment
(Mode b: adjustment once). The timing for line position adjustment depends on
the combinations of several conditions. Section Descriptions" section.
Elapse Time
009 Adjust the time threshold for the line position adjustment (Mode b: adjustment
once). The timing for line position adjustment depends on the combinations of
several conditions.
Temp Change 2
011 Adjust the temperature change threshold for the line position adjustment
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions.
Elapse Time 2
012 Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions.
016 Page: Power ON:BW+FC
2194
[MUSIC Exe Result] Line Position Adjustment: Execution Result
001 Year
002 Month
003 Date
SM Appendix
*ENG
[0 to 999 / 100 / 1 page/step]
*ENG
[0 to 100 / 5 / 1deg/step]
*ENG
[1 to 1440 / 300 / 1 minute/step]
*ENG
[0 to 100 / 10 / 1deg/step]
*ENG
[1 to 9999 / 600 / 1 minute/step]
*ENG
[0 to 999 / 200 / 1 page/step]
*ENG
[0 to 99 / 0 / 1 year/step]
*ENG
[1 to 12 / 1 / 1 month/step]
*ENG
[1 to 31 / 1 / 1 day/step]
9-51
System Service Mode
D037/D038/D040/D041

Advertisement

Table of Contents
loading