System Service Mode
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat Number: ACC
Specifies the maximum number of repeats of the toner density adjustment at
ACC.
0: Disabled, 1 to 3: Repeat number,
004
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat Number: Recovery
005
Not used
Repeat Number: Job End
Specifies the maximum number of repeats of the toner density adjustment at
job end.
0: Disabled, 1 to 3: Repeat number,
006
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat: Interrupt
007
Specifies the maximum number of repeats of the toner density adjustment
during printing. DFU
Toner Supply Coeff.
008
Adjusts the time for the toner supply mode when a toner density is detected to
be low.
C-pattern: Bk
009
Specifies the belt mark generating time for checking the black toner density
D037/D038/D040/D041
*ENG
[0 to 9 / 3 / 1 time/step]
*ENG
[0 to 9 / 3 / 1 time/step]
*ENG
[0 to 9 / 4 / 1 time/step]
*ENG
[0 to 9 / 0 / 1 time/step]
*ENG
[0 to 25.5 / 10 / 0.1 sec/step]
*ENG
[0 to 255 / 5 / 1 time/step]