System Service Mode
004 Absolute Humidity: Thresh 2
005 Absolute Humidity: Thresh 3
006 Absolute Humidity: Thresh 4
007 Current Temp.: Display
008 Relative Humidity: Display
009 Absolute Humidity: Display
Previous Envir. Range:
010
Display
011 Previous Temp.: Display
012 Relative Humidity: Display
013 Absolute Humidity: Display
D037/D038/D040/D041
between LL and ML.
[0 to 100 / 4.3 / 0.01 g/m
Changes the humidity threshold
*ENG
between ML and MM.
[0 to 100 / 11.3 / 0.01 g/m
Changes the humidity threshold
*ENG
between MM and MH.
[0 to 100 / 18.0 / 0.01 g/m
Changes the humidity threshold
*ENG
between MH and HH.
[0 to 100 / 24.0 / 0.01 g/m
Displays the current temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the current relative humidity.
*ENG
[0 to 100 / 0 / 1%RH/step]
Displays the absolute humidity.
*ENG
[0 to 100 / 0 / 0.01 g/m
Displays the previous environmental
condition, which is measured in
*ENG
absolute humidity.
[1 to 5 / – / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Displays the previous temperature.
*ENG
[0 to 100 / 0 / 1 deg/step]
Displays the previous relative
*ENG
humidity.
[0 to 100 / 0 / 1%RH/step]
Displays the previous absolute
*ENG
humidity.
[0 to 100 / 0 / 0.01 g/m
9-28
3
/step]
3
/step]
3
/step]
3
/step]
3
/step]
3
/step]
SM Appendix