(High temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
2012
[Charge Output Control]
001 AC Voltage
2013
[Envir. Correct:PCU]
001 Envir. Range:FC:Display
002 Forced Setting
003 Absolute Humidity: Thresh 1
SM Appendix
*ENG
[0 to 3000 / 860 / 10 ųA/step]
*ENG
*ENG
[0 to 3000 / 840 / 10 ųA/step]
*ENG
[0 to 3000 / 940 / 10 ųA/step]
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
*ENG
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)
Displays the environmental condition,
which is measured in absolute
humidity.
[1 to 5 / – / 1 /step]
*ENG
1: LL (LL <= 4.3 g/m
2: ML (4.3 < ML <= 11.3 g/m
3: MM (11.3 < MM <= 18.0 g/m
4: MH (18.0 < MH <= 24.0 g/m
5: HH (24.0 g/m
Selects the environmental condition
manually.
[0 to 5 / 0 / 1 /step]
*ENG
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
*ENG
Changes the humidity threshold
9-27
System Service Mode
3
)
3
)
3
)
3
)
3
< HH)