Copy Data Security Unit Type F (B829)
5.
Attach the ICIB-3 (copy data security board) [A] to CN 504 [B] on the BCU (
6.
Reassemble the machine.

User Tool Setting

1.
Plug in and turn on the main power switch.
2.
Go into the User Tools mode, and select System Settings > Administrator Tools > Copy
Data Security Option > "On".
3.
Exit User Tools.
4.
Check the operation.
The machine will issue an SC165 error if the machine is powered on with the
ICIB-3 removed and the "Data Security for Copying "feature set to "ON".
When you remove this option from the machine, first set the setting to "OFF"
with the user tool before removing this board. If you forget to do this, "Data
Security for Copying "feature cannot appear in the user tool setting. And then
SC165 will appear every time the machine is switched on, and the machine
cannot be used.
Make sure that the machine can recognize the option (see "Check All Connections" at the
end of this section).
D037/D038/D040/D041
2-72
x 2).