Absolute Humidity: Threshold 2
004
Adjusts the threshold value between ML and MM.
Absolute Humidity: Threshold 3
005
Adjusts the threshold value between MM and MH.
Absolute Humidity: Threshold 4
006
Adjusts the threshold value between MH and HH.
007 Temp Threshold
[Paper Size Correction]
2308
Adjusts the threshold value for the paper size correction.
001 Threshold 1
002 Threshold 2
003 Threshold 3
004 Threshold 4
SM Appendix
*ENG
[0 to 100 / 8 / 0.01 g/m
*ENG
[0 to 100 / 16 / 0.01 g/m
*ENG
[0 to 100 / 24 / 0.01 g/m
*ENG
[–5 to 30 / 5 / 1 deg/step]
[0 to 350 / 290 / 1 mm/step]
*ENG
Threshold 1 ≤ paper:
Paper is detected as "S1" size.
[0 to 350 / 250 / 1 mm/step]
*ENG
Threshold 2 ≤ paper ≤ Threshold 1:
Paper is detected as "S2" size.
[0 to 350 / 194 / 1 mm/step]
*ENG
Threshold 3 ≤ paper ≤ Threshold 2:
Paper is detected as "S3" size.
[0 to 350 / 150 / 1 mm/step]
Threshold 4 ≤ paper ≤ Threshold 3:
*ENG
Paper is detected as "S4" size.
Paper ≤ Threshold 4:
Paper is detected as "S5" size.
9-55
System Service Mode
3
/step]
3
/step]
3
/step]