System Service Mode
2971
[BW Non-Image:Bias ON]
001 T1 BW:Bias On:Normal
003 T1 BW:Bias On:Low
SP3-XXX (Process)
3011
[Process Cont. Manual Execution]
001 Normal Procon
002 Toner Density Adjust
003 Procon BF-ACC
004 With Full MUSIC
005 With Normal MUSIC
D037/D038/D040/D041
*ENG
[-360 to 180 / 0 / 10 msec/step]
*ENG
[0 or 1 / 0 / 1 /step]
Executes the normal process control
-
manually (potential control).
Check the result with SP3-325-001 after
executing this SP.
[0 or 1 / 0 / 1 /step ]
Executes the toner density adjustment
-
manually. Check the result with
SP3-325-001 after executing this SP.
[0 or 1 / 0 / 1 /step ]
Executes the process control that is
-
normally done before ACC.
The type of process control is selected with
SP3-041-004.
[0 or 1 / 0 / 1 /step ]
Executes the process control that is
-
normally done at the same time as MUSIC.
This SP does the MUSIC (line position
adjustment) twice.
[0 or 1 / 0 / 1 /step ]
Executes the process control that is
-
normally done at the same time as MUSIC.
This SP does the MUSIC (line position
adjustment) once.
9-112