[Stamp Data Download]
Use this SP to download the fixed stamp data stored in the firmware of the
ROM and copy it to the HDD. This SP can be executed as many times as
5853
required. This SP must be executed after replacing or formatting the hard
disks.
This SP can be executed only with the hard disks installed.
[Remote ROM Update]
5856
Allows the technician to upgrade the firmware using a local port (IEEE1284)
when updating the remote ROM.
002 Local Port
5857
[Save Debug Log]
On/Off (1:ON 0:OFF)
001
Switches the debug log feature on and off. The debug log cannot be captured
until this feature is switched on.
Target (2: HDD 3: SD)
002 Selects the storage device to save debug logs information when the
conditions set with SP5-858 are satisfied.
[ 2 to 3 / 2 / 1 /step]
Save to HDD
Saves the debug log of the input SC number in memory to the HDD.
005
A unique file name is generated to avoid overwriting existing file names on
the SD Card. Up to 4MB can be copied to an SD Card. 4 MB segments can
be copied one by one to each SD Card.
006 Save to SD Card
SM Appendix
[0 to 1 / 0 / 1/step]
*CTL
0: Disable
1: Enable
*CTL
-
0: OFF, 1: ON
2: HDD, 3: SD Card
9-241
System Service Mode
D037/D038/D040/D041
Need help?
Do you have a question about the D037 and is the answer not in the manual?