Ricoh D037 Service Manual page 685

Hide thumbs Also See for D037:
Table of Contents

Advertisement

[Toner End Prohibition Setting]
3519
Enables or disables each adjustment at toner near end.
001 Process Control
002 MUSIC
003 TC Adjustment
3520
[ITB Idling Rotation]
001 Temperature: High
002 Temperature: Medium
003 Temperature: Low
004 Temperature: L: Power ON
005 Temp. Range Thresh:T2
006 Temp. Range Thresh:T2
Temp. Thresh Temp.
010
Thresh:High
Temp. Thresh Temp.
011
Thresh:Low
[Initial Process Control Setting]
Adjusts the threshold for the process control at power on.
3522
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at power on is executed.
002 Non-use Time Setting
003 Temperature Range
SM Appendix
*ENG
[0 or 1 / 1 / 1/step]
0: Permit (adjustment is done even toner
*ENG
near end condition)
1: Forbid (adjustment is not done at toner
*ENG
near end condition)
*ENG
*ENG
[0 or 3 / 0 / 1 revolution/step]
*ENG
*ENG
*ENG
[20 or 30 / 30 / 1 deg/step]
*ENG
[0 or 15 / 15 / 1 deg/step]
*ENG
[0 or 50 / 30 / 1 deg/step]
*ENG
[0 or 50 / 15 / 1 deg/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]