Access Control - Ricoh D037 Service Manual

Hide thumbs Also See for D037:
Table of Contents

Advertisement

System Service Mode
this SP is not activated even if this SP is set to "1".
Rule Set (Start)
Specifies the start setting for the summer time mode.
There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the
first digit, so the eight-digit setting for -2 or -3 becomes a seven-digit setting.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [1 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
003
5th and 6th digits: The hour. [00 to 23]
7th digit: The length of the advanced time. [0 to 9 / 1 hour /step]
8th digit: The length of the advanced time. [0 to 5 / 10 minutes /step]
For example: 3500010 (EU default)
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
Rule Set (End)
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
004
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".

[Access Control]

5401
When installing the SDK application, SAS (VAS) adjusts the following
settings. DFU
103 Default Document ACL
D037/D038/D040/D041
-
-
-
Whenever a new login user is added to
*CTL
the address book in external certification
mode (for Windows, LDAP, RDH), the
9-196
SM Appendix