System Service Mode
002 Plain: M
003 Plain: C
004 Plain: Y
009 Thick 2: Bk
010 Thick 2: M
011 Thick 2: C
012 Thick 2: Y
[Ambient Temp/Hum:Display]
2241
Displays the environment temperature and humidity.
001 Temperature
002 Relative Humidity
003 Absolute Humidity
[Env. Correct:Transfer]
2302
Environmental Correction: Image Transfer Belt Unit
Forced Setting
Sets the environment condition manually.
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
002
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
Absolute Humidity: Threshold 1
003
Adjusts the threshold value between LL and ML.
D037/D038/D040/D041
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
-
[–1280 to 1270 / - / 0.1deg/step]
-
[0 to 1000 / - / 0.1 %RH/step]
-
[0 to 100 / - / 0.1 g/m
*ENG
[0 to 6 / 0 / 1 /step]
*ENG
[0 to 100 / 4 / 0.01 g/m
9-54
3
/step]
3
/step]
SM Appendix