System Service Mode
004 Relative Humidity Range
005 Absolute Humidity Range
[Rapi_timer]
100
[Time Setting]
[Non-use Time Process Control Setting]
Adjusts the threshold for the process control at stand-by.
3531
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at stand-by is executed.
001 Non-use Time Setting
002 Temp. Range
003 Relative Humidity Range
004 Absolute Humidity Range
Maximum Execution
005
Number
3611
[Dev. Gamma: Display/Set]
001 Bk (Current)
002 C (Current)
003 M (Current)
004 Y (Current)
005 Bk (Target Display)
D037/D038/D040/D041
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
*ENG
[0 to 255 / 30 / 1 sec/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
Adjusts the maximum execution time for
*ENG
the process control at stand-by.
[0 to 99 / 10 / 1 time/step]
Displays the current development gamma
*ENG
for Bk
[0 to 5 / 0.9 / 0.01 mg/cm
*ENG
Displays the current development gamma
for C/M/Y.
*ENG
[0 to 5 / 0.8 / 0.01 mg/cm
*ENG
Displays the target development gamma
*ENG
for Bk.
9-152