5504
[Jam Alarm]
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
001
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
5505
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 -
5507
[Supply Alarm]
001 Paper Supply Alarm
002 Staple Supply Alarm
003 Toner Supply Alarm
080 Toner Call Timing
128 Interval :Others
132 Interval :A3
133 Interval :A4
SM Appendix
*CTL
-
*CTL
[0 to 255 / 20 / 100 copies /step]
*CTL
-
0: Off, 1: On, DFU
0: Off, 1: On, Japan only
0: Off, 1: On, DFU
Changes the timing of the "Toner Supply Call" via
the @Remote, when the following conditions
occur.
0: At replacement
1: At near end
[250 to 10000 / 1000 / 1 /step] DFU
9-203
System Service Mode
D037/D038/D040/D041