When Installing The Fusing Unit - Ricoh D037 Service Manual

Hide thumbs Also See for D037:
Table of Contents

Advertisement

Fusing
4.
Open the paper transfer unit [A]
5.
Release the lock levers [B].
6.
Hold the fusing unit handles [C], and then pull out the fusing unit.

When installing the fusing unit

Make sure that the both lock levers [B] are locked before closing the duplex unit. Otherwise,
these lock levers [B] can be broken.
4.11.3 ENTRANCE GUIDE PLATE
1.
Fusing unit (
Section: Fusing Unit)
2.
Entrance Guide Plate [A] (
Cleaning Requirement
The entrance guide plate requires cleaning maintenance at every 60 K interval. Clean the
entrance guide plate with a cloth moistened with alcohol at the following points.
D037/D038/D040/D041
x 2)
4-82