System Service Mode
3014
[TD Sen Initial Set Result] Developer Initialization Result: Display
Display: YCMK
001 Displays the developer initialization result. See the "Error Condition Tables" in
the Process Control Error section for details on the meaning of each code.
All colors are displayed. Values are displayed in the order Y C M Bk.
e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others
succeeded.
3015
[Forced Toner Supply] Forced Toner Supply ([Color])
001 Execution: ALL
002 Execution: COL
003 Execution: Bk
004 Execution: C
005 Execution: M
006 Execution: Y
[Forced Toner Supply Cntl] Forced Toner Supply Setting ([Color])
3016
Specifies the manual toner supply time for each color.
001 Supply Time: Bk
002 Supply Time: C
003 Supply Time: M
004 Supply Time: Y
3020
[Vt Limit Error]
D037/D038/D040/D041
[0000 to 9999 / - / 1 /step ]
*ENG
1: Success
2 to 9: Failure
-
-
[0 or 1 / 0 / 1 /step]
-
Executes the manual toner supply to
-
the development unit.
-
-
*ENG
*ENG
[0 to 30 / 4 / 1 sec/step]
*ENG
*ENG
9-114