System Service Mode
status the Basil unit cannot answer a polling request.
2: The Cumin device is set. In this status the Basil unit cannot answer a
polling request.
3: The NRS device is being set. In this status the Cumin device cannot be set.
4: The NRS module has not started.
202 Letter Number
203 Confirm Execute
204 Confirm Result
Displays a number that indicates the result of the inquiry executed with
SP5816 203.
0: Succeeded
1: Inquiry number error
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Inquiry executing
Confirm Place
205 Displays the result of the notification sent to the device from the GW URL in
answer to the inquiry request. Displayed only when the result is registered at
the GW URL.
206 Register Execute
Register Result
Displays a number that indicates the registration result.
207
0: Succeeded
2: Registration in progress
3: Proxy error (proxy enabled)
D037/D038/D040/D041
Allows entry of the number of the request needed
for the Cumin device.
Executes the inquiry request to the NRS GW URL.
Executes Cumin Registration.
9-220
SM Appendix