3: Cannot detect dial tone automatically
4: Line is disconnected
5: Insufficient electrical power supply
6: Line classification not supported
7: Error because fax transmission in progress – ioctl() occurred.
8: Other error occurred
9: Line classification still in progress. Please wait.
Selection Dial/Push
This SP displays the classification (tone or pulse) of the telephone line to the
access point for Cumin-M. The numbered displayed (0 or 1) is the result of
the execution of SP5816 151. However, this setting can also be changed
manually.
[0 to 1/ 0 / 1 /step]
153
0: Tone Dialing Phone
1: Pulse Dialing Phone
Inside Japan "2" may also be displayed:
0: Tone Dialing Phone
1: Pulse Dialing Phone 10PPS
2: Pulse Dialing Phone 20PPS
Outside Line/Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for
Cumin-M in a system that employs a PBX (internal line).
If the execution of SP5816 151 has succeeded and Cumin-M has
connected to the external line, this SP display is completely blank.
154
If Cumin-M has connected to an internal line, then the number of the
connection to the external line is displayed.
If Cumin-M has connected to an external line, a comma is displayed with
the number. The comma is inserted for a 2 sec. pause.
The number setting for the external line can be entered manually
(including commas).