Ricoh D037 Service Manual page 678

Hide thumbs Also See for D037:
Table of Contents

Advertisement

System Service Mode
3421
[Toner Supply Range]
001 Upper Limit: Bk
002 Upper Limit: C
003 Upper Limit: M
004 Upper Limit: Y
005 Minimum Supply Time: Bk
006 Minimum Supply Time: C
007 Minimum Supply Time: M
008 Minimum Supply Time: Y
3451
[T-Supply Carry Over: Display] DFU
001 Bk
002 C
003 M
004 Y
3452
[Toner Supply Carry Over: Setting] DFU
001 Maximum: Bk
002 Maximum: C
003 Maximum: M
004 Maximum: Y
[Process Control Target M/A]
3501
Adjusts the target M/A.
D037/D038/D040/D041
*ENG
Adjusts the toner supply rate during
*ENG
printing.
*ENG
[0 to 100 / 100 / 1%/step]
*ENG
*ENG
Adjusts the minimum toner supply
*ENG
time.
*ENG
[0 to 1000 / 0 / 1 msec/step]
*ENG
*ENG
*ENG
[0 to 10000 / 0 / 1 msec/step]
*ENG
*ENG
*ENG
*ENG
[0 to 10000 / 1000 / 1 msec/step]
*ENG
*ENG
9-144