SC Tables
No.
Type
Log Data Error
CTL
An error was detected in the handling of the log data at power on or
876
D
during machine operation. This can be caused by switching the
machine off while it is operating.
Log Data Error 1
-001
Initialize the HDD with SP5832-004.
Log Data Error 2
-002
1.
2.
Log Data Error 3
-003
1.
2.
Log Data Error 4
-004
Initialize the HDD with SP5832-004.
Log Data Error 5
-005
1.
2.
-099
Log Data Error 99
D037/D038/D040/D041
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Damaged log data file in the HDD
An encryption module not installed
Disable the log encryption setting with SP9730-004 ("0" is off.)
Install the DESS module.
Invalid log encryption key due to defective NVRAM data
Initialize the HDD with SP5832-004.
Disable the log encryption setting with SP9730-004 ("0" is off.)
Unusual log encryption function due to defective NVRAM data
Installed NVRAM or HDD which is used in another machine
Reinstall the previous NVRAM or HDD.
Initialize the HDD with SP5832-004.
Other than the above causes
4-64