1) Print the ACC test pattern (User tools > Maintenance > ACC > Start).
2) Put the printout on the exposure glass.
3) Put 10 sheets of white paper on top of the test chart.
4) Close the ARDF or the platen cover.
5) Press "Start Scanning" on the LCD panel. The machine starts the ACC.
6.
Check that the sample image has been copied normally.
7.
Open the front cover.
8.
Remove the instruction guide sheet [A], and make sure the SMC report [B] is stored as
shown above. Then replace the instruction guide sheet.

Settings Relevant to the Service Contract

Change the necessary settings for the following SP modes if the customer has made a
service contract.
You must select one of the counter methods (developments/prints) in accordance
with the contract ( SP5045-001).
Counting method
SP No.
Specifies if the counting method used in
meter charge mode is based on
SP5-045-001
developments or prints. NOTE: You can set
this one time only. You cannot change the
setting after you have set it for the first time.
A3/11" x 17" double counting
SP No.
SM
Function
Function
2-15
Copier Installation
Default
"0": Developments
Default
D037/D038/D040/D041