Ricoh D037 Service Manual page 695

Hide thumbs Also See for D037:
Table of Contents

Advertisement

NOTE:
If the toner collection bottle has been replaced before the machine detects
used toner near full when this setting is set to "0", the machine cannot detect
toner collection bottle near full. In that case, set SP3-902-017 to "1".
Day Thresh:NF
012 Sets the threshold days for the near-full display. The near-full of the toner
collection bottle is displayed after the toner collection full sensor has detected
the actuator in the toner collection bottle.
013 Total Collected Toner
014 Full Detected Date
[New PCU Detection]
3901
Turns new PCU detection on or off.
001 ON/OFF Setting
[Manual New Unit Set]
Turns the new unit detection flag for each PM unit on or off.
3902
The use of these counters is explained in the PM section and in the relevant
parts of section 3 (Replacement and Adjustment).
001 Development Unit: Bk
002 Development Unit: C
003 Development Unit: M
004 Development Unit: Y
005 Developer: Bk
SM Appendix
*ENG
[1 to 30 / 10 / 1 day/step]
Displays the total amount of the used
*ENG
toner.
[0 to 999999999 / 1 / 1]
Displays the date of the full detection fot
*ENG
the toner collection bottle.
[0 or 1 / 1 / - ]
*ENG
0: OFF, 1: ON
*ENG
*ENG
[0 or 1 / 0 / - ]
0: OFF, 1: ON
*ENG
*ENG
*ENG
[0 or 1 / 0 / - ]