Replacing The Axis-2 Cabling - ABB CRB 15000 Product Manual

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5.3.3 Replacing the axis-2 cabling

Location of the cable harness
The cable harness is located as shown in the figure.
xx2100000058
Summary of the replacement procedure
This is a brief summary of the replacement procedure, containing the major actions
to be performed.
Required spare parts
Spare part
Cable harness, joint 2
Product manual - CRB 15000
3HAC077389-001 Revision: A
1 Remove the swing cover.
2 Remove the lower arm cover and inner lower arm cover.
3 Disconnect the joint-2 cabling.
4 Replace the cabling.
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the CRB 15000 via myABB Business Portal,
www.abb.com/myABB.
© Copyright 2021 ABB. All rights reserved.
5.3.3 Replacing the axis-2 cabling
Article number
Note
3HAC073205-001
Also order new Cable tie:
3HAC075545-001.
5 Repair
Continues on next page
137